| Part Number | GVMRB180KG65S |
|---|---|
| UPC | 731304326526 |
| UPC11 | 73130432652 |
| EAN | 0731304326526 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| Depth | 33.62 inch |
| Height | 77.56 inch |
| Width | 39.45 inch |
| Weight | 1497.93 pound |
| Presentation | Highly compact, energy efficient, redundant 3-phase UPS for data center, facility and industrial applications. |
|---|---|
| Lead Time | Usually Ships within 2 Weeks |
| Provided Equipment | Installation guide Start-Up Service |
| Bypass Voltage Tolerance | +/-10% settable from +/-4/6/8 and 10% |
| Max Bypass Input Current | 217 A |
| Bypass Current Protection | 400 A |
| Colour | White |
| Depth | 33.62 in (85.4 cm) |
| Height | 77.56 in (197 cm) |
| Product Weight | 1497.93 lb(US) (679.45 kg) |
| Width | 39.45 in (100.2 cm) |
| Network Frequency | 40 - 70 Hz |
| Number Of Input Connectors | 1 Hard Wire 3-wire (3PH + G) |
| Input Voltage Limits | 360...576 V adjustable 480 V 360...576 V 480 V |
| Maximum Input Current | 278 A |
| Switching Current Capacity | 400 A |
| Max Short Time Withstd Current | 65 kA |
| Input Harmonic Distortion | Less than 3% for full load |
| Input Protection Type | 3-pole breaker |
| Input Voltage | 3 phase |
| Rated Power In W | 162000 W |
| Max Configurable Power In W | 162000 W |
| Harmonic Distortion | Less than 2% |
| Output Frequency | 50/60 Hz +/- 1 Hz sync to mains 50/60 Hz +/- 1 Hz not synced |
| Crest Factor | Unlimited |
| Ups Type | Double Conversion Online |
| Wave Type | Sine wave |
| Output Connector Type | Hard Wire 4-wire (3PH + G) 1 Hard Wire 5-wire (3PH + N + G) 1 |
| Output Voltage Tolerance | +/- 1% static and +/- 3% at 100% load step |
| Output Harmonic Distortion | < 2% linear load and < 3% non-linear load |
| Output Overload Operation | 10 minutes @ 125% and 60 seconds @ 150% |
| Req Output Current Protection | 300 A |
| Neutral Output Current | 195 A |
| Bypass Type | Built-in Static Bypass |
| Output Voltage | 480 V 3 phase |
| Product Certifications | CUL Listed ENERGY STAR V2.0 (USA) FCC part 15 class A UL 1778 |
| Standards | EN/IEC 62040-3 IBC 2012 and CBC2013 to Sds=2.02g OSHPD |
| Ambient Air Temp For Op | 32…104 °F (0…40 °C) |
| Relative Humidity | 0…95 % |
| Operating Altitude | 0...3333 ft |
| Ambient Air Temp For Storage | -13…131 °F (-25…55 °C) |
| Storage Altitude | 0…49212 ft (0.00…14999.82 m) |
| Acoustic Level | 65 dBA |
| Heat Dissipation | 21160 Btu/h |
| IP Degree Of Protection | IP20 |
| Battery Type | External battery system |
| Battery Voltage | 480V |