Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Easergy P3U 3CT 1Io ringlug 4VT 16DI 8DO 48-230V DI110V 2RJ45 ANSI
REL52056
Easergy P3U 3CT 1Io ringlug 4VT 16DI 8DO 48-230V DI110V 2RJ45 ANSI
Specifications
Part Number REL52056
Country of Origin US
UPC 606481465467
UPC11 60648146546
EAN 3606481465467
Availability N
Lead Time 71
UNSPSC 39121106
ECCN EAR99
HTs Code 8537109170
Discount Schedule PL1S
Return Indicator Yes
Depth 8.07 inch
Height 6.67 inch
Width 6.69 inch
Weight 5.51 pound
Characteristics
Range Of Product Easergy P3
Product Or Component Type Protection relay
Relay Application Universal
Product Reference P3U30-6AAA2BCAB
Device Mounting Flush
Power Supply 48...230 V AC/DC
Measuring Inputs 3 1/5 A CT phase current 1 1/5 A CT residual current 4 100 V/110 V VT voltage
Number Of Sensors 0 temperature 0 arc
Number Of Digital Inputs (Di) 16.0
Number Of Digital Outputs (Do) 8 DO 1 watchdog
Communication Ports Front USB port 1 Rear RJ45 2
Communication Protocols IEC 61850 ed. 1 IEC 61850 ed. 2 IEC 60870-5-101 DNP3 TCP Modbus TCP Ethernet/IP
Redundancy Com Port Protocol RSTP PRP
Cybersecurity Password protection Port hardening
Protection Functions Phase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Capacitor bank unbalance 51C Broken conductor 46 I2/I1 Cold load pick-up H2 detection 68H2 H5 detection 68H5 Breaker failure 50BF Switch ON to fault (SOTF) Directional active underpower 37P Fault locator 21FL Recloser 79 Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR Motor restart inhibition 66 Capacitor overvoltage 59C Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Earth fault overvoltage 59N Underfrequency 81/81N Rate of change of frequency 81R Synchro-check 25 Lockout relay 86 CT supervision 60 VT supervision 60 Programmable stages 99 Programmable curve
Arc Flash Protection No
Measurement Functions Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Short circuit fault reactance Fault location current Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Voltage phasor diagram view Current phasor diagram view Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Condition monitoring CB wear Voltage interruption
Control Functions Switchgear control and monitoring Programmable switchgear interlocking Local control on single-line diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with Easergy SmartApp Web-server
Controllable Switchgear Devices 4 controlled + 8 displayed
Number Of Setting Groups 4
Monitoring Functions Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring
Logs And Records Event recording Disturbance recording Tripping context
Switchgear Diagnosis Type CT supervision Trip circuit supervision TCS
Connections - Terminals Screw Ring lugs Pin
Operating Threshold 110 V AC/DC
Time Synchronisation Protocol SNTP
Web Server Embedded HTTP server
Display Type LCD LCD
Number Of Key 2 customizable
Local Signalling 4 LEDs 8 LEDs programmable
Height 6.67 in (169.5 mm)
Width 6.69 in (170 mm)
Depth 8.07 in (205 mm)
Product Weight 5.51 lb(US) (2.5 kg) maximum
Electromagnetic Compatibility Emission tests IEC/EN 60255-26 ed. 3 Emission tests class A CISPR 11 Emission tests class A CISPR 22 EMC immunity IEC/EN 60255-26 ed. 3 EMC immunity EN/IEC 61000-4-18 EMC immunity IEC 60255-22-1 EMC immunity level 4 EN/IEC 61000-4-2 EMC immunity IEC 60255-22-2 EMC immunity level 3 EN/IEC 61000-4-3 EMC immunity IEC 60255-22-3 EMC immunity level 4 EN/IEC 61000-4-4 EMC immunity IEC 60255-22-4 EMC immunity level 3 EN/IEC 61000-4-5 EMC immunity IEC 60255-22-5 EMC immunity level 3 EN/IEC 61000-4-6 EMC immunity IEC 60255-22-6 EMC immunity EN/IEC 61000-4-8 EMC immunity level 5 EN/IEC 61000-4-9 EMC immunity EN/IEC 61000-4-29 EMC immunity EN/IEC 61000-4-11 EMC immunity EN/IEC 61000-4-17 EMC immunity IEC 60255-27 EMC immunity class III IEC 60255-5 EMC immunity EN/IEC 60255-1
Mechanical Robustness Vibrations class II) IEC 60255-21-1 VibrationsFc IEC 60068-2-6 Shocks class II) IEC 60255-21-2 ShocksEa IEC 60068-2-27 Seismic tests method A class II) IEC 60255-21-3
Climatic Withstand Exposure to dry heat Bd EN/IEC 60068-2-2 Exposure to cold Ad EN/IEC 60068-2-1 Exposure to damp heat in service Db EN/IEC 60068-2-30 Exposure to damp heat in service Cab EN/IEC 60068-2-78
Ambient Air Temp For Op -40…149 °F (-40…65 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
IP Degree Of Protection IP54 IEC 60529
Relative Humidity 0…95 %, without condensation
Maximum Operating Altitude 6561.68 ft (2000 m)
Protective Treatment Conformal coating
Category 11405 - EASERGY P3 PROTECTIVE RELAYS
Discount Schedule PL1S
GTIN 03606481465467
Nbr. Of Units In Pkg. 1
Country Of Origin US
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews