Specifications
Part Number REL52132
Country of Origin US
UPC 606481465665
UPC11 60648146566
EAN 3606481465665
Availability N
Lead Time 50
UNSPSC 83101808
HTs Code 8536490055
Discount Schedule PL1S
Return Indicator Yes
Depth 9.06 inch
Height 6.93 inch
Width 10.63 inch
Weight 9.26 pound
Characteristics
Range Of Product Easergy P3
Product Or Component Type Protection relay
Relay Application Transformer
Product Reference P3T32-CCG1A-DA1FA-BBAAB
Device Mounting Flush
Power Supply 48...230 V AC/DC
Measuring Inputs 6 1/5 A CT phase current 2 5/1 A CT residual current 1 1/0.2 A CT residual current 4 100 V/110 V VT voltage
Number Of Sensors 0 temperature 0 arc
Number Of Digital Inputs (Di) 6.0
Number Of Digital Outputs (Do) 10 DO 1 watchdog
Communication Ports Front USB port 1 Rear RJ45 1 Rear RS485 1
Communication Protocols IEC 61850 ed. 1 IEC 61850 ed. 2 IEC 60870-5-101 DNP3 TCP Modbus TCP Ethernet/IP IEC 60870-5-103 DNP3 Modbus RTU DeviceNet SPAbus
Cybersecurity Password protection Port hardening
Protection Functions Overfluxing (V/Hz) 24 Synchro-check 25 Undervoltage 27 Directional active underpower 37P Negative sequence overcurrent 46 Thermal overload protection 49 Earth fault overcurrent 50N/51N Phase overcurrent 50/51 Breaker failure 50BF Switch ON to fault (SOTF) Capacitor bank unbalance 51C Capacitor overvoltage 59C Overvoltage 59 Earth fault overvoltage 59N Restricted earth fault 64REF Directional phase overcurrent 67 Directional earth fault 67N H2 detection 68H2 H5 detection 68H5 Underfrequency 81/81N Rate of change of frequency 81R Lockout relay 86 Two-winding transformer differential 87T Programmable stages 99 Programmable curve Cold load pick-up
Arc Flash Protection Yes
Relay Type Differential current relay
Measurement Functions Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Short circuit fault reactance Fault location current Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Voltage phasor diagram view Current phasor diagram view Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Condition monitoring CB wear Voltage interruption
Control Functions Switchgear control and monitoring Programmable switchgear interlocking Local control on single-line diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with Easergy SmartApp Web-server
Controllable Switchgear Devices 3 controlled + 5 displayed
Number Of Setting Groups 4
Monitoring Functions Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring
Logs And Records Event recording Disturbance recording Tripping context
Switchgear Diagnosis Type CT/VT supervision Trip circuit supervision TCS
Connections - Terminals Screw Ring lugs Pin
Operating Threshold 110 V AC/DC
Time Synchronisation Protocol SNTP
Web Server Embedded HTTP server
Display Type LCD LCD
Number Of Key 2 customizable
Local Signalling 2 LEDs 16 LEDs programmable
Height 6.93 in (176 mm)
Width 10.63 in (270 mm)
Depth 9.06 in (230 mm)
Product Weight 9.26 lb(US) (4.2 kg) maximum
Electromagnetic Compatibility Emission tests IEC/EN 60255-26 ed. 3 Emission tests class A CISPR 11 Emission tests class A CISPR 22 EMC immunity IEC/EN 60255-26 ed. 3 EMC immunity EN/IEC 61000-4-18 EMC immunity IEC 60255-22-1 EMC immunity level 4 EN/IEC 61000-4-2 EMC immunity IEC 60255-22-2 EMC immunity level 3 EN/IEC 61000-4-3 EMC immunity IEC 60255-22-3 EMC immunity level 4 EN/IEC 61000-4-4 EMC immunity IEC 60255-22-4 EMC immunity level 3 EN/IEC 61000-4-5 EMC immunity IEC 60255-22-5 EMC immunity level 3 EN/IEC 61000-4-6 EMC immunity IEC 60255-22-6 EMC immunity EN/IEC 61000-4-8 EMC immunity level 5 EN/IEC 61000-4-9 EMC immunity EN/IEC 61000-4-29 EMC immunity EN/IEC 61000-4-11 EMC immunity EN/IEC 61000-4-17 EMC immunity IEC 60255-27 EMC immunity class III IEC 60255-5 EMC immunity EN/IEC 60255-1
Mechanical Robustness Vibrations class II) IEC 60255-21-1 VibrationsFc IEC 60068-2-6 Shocks class II) IEC 60255-21-2 ShocksEa IEC 60068-2-27 Seismic tests method A class II) IEC 60255-21-3
Climatic Withstand Exposure to dry heat Bd EN/IEC 60068-2-2 Exposure to cold Ad EN/IEC 60068-2-1 Exposure to damp heat in service Db EN/IEC 60068-2-30 Exposure to damp heat in service Cab EN/IEC 60068-2-78
Ambient Air Temp For Op -40…149 °F (-40…65 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
IP Degree Of Protection IP54 IEC 60529
Relative Humidity 0…95 %, without condensation
Maximum Operating Altitude 6561.68 ft (2000 m)
Protective Treatment Conformal coating
Category 11405 - EASERGY P3 PROTECTIVE RELAYS