This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 2 normally closed + 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.1A at 250V AC, 1.5A at 240V AC and a conventional enclosed thermal current of 6A. It is furnished with screw clamp terminals for electrical connection and 1 tapped entry for ISO M20 cable gland. The trigger cable anchor point at left hand side. It can reset by booted pull button. It offers long mechanical durability which is about 100000 operating cycles. It is an IP66 and IP67 rated product. The casing is made of Zamak (red) with stainless steel cover. Its dimensions are 40mm (Width) x 64.2mm (Depth) x 201mm (Height) and weighs 0.455kg. It is intended for all machine applications like woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. This product is certified by CCC, CSA and UL. It meets CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, UL 508 Machinery directive 2006/42/EC and Work equipment directive 2009/104/EC standards. These emergency stop rope pull switches can be equipped with trip indicators, cable tension adjustment can be performed using a turnbuckle. The emergency stop rope pull switch is intended for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. The emergency stop rope pull switch is designed to avert hazards (dangerous phenomena) at the earliest possible moment or to reduce risks which could cause injury to persons or damage either to machines or work in progress.
Brand: Telemecanique
Add to Quote CataloguePart Number | XY2CJS19H29 |
---|---|
Country of Origin | ID |
UPC | 389119619554 |
UPC11 | 38911961955 |
EAN | 3389119619554 |
Availability | N |
Lead Time | 55 |
UNSPSC | 39122213 |
HTs Code | 8536509065 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | Yes |
Weight | 1.00 pound |
Range Of Product | Preventa XY2 |
---|---|
Product Or Component Type | Latching emergency stop rope pull switch |
Device Short Name | XY2C |
Housing Colour | Red RAL 3000 |
Overvoltage Category | Class I EN/IEC 61140 |
Local Signalling | Color indicator |
Number Of Cables | 1 |
Trigger Cable Maximum Length | 65.62 ft (20 m) |
Body Material | Zamak |
Head Material | PA (polyamide) |
Cover Material | Galvanised steel |
Reset | By pull button |
Contacts Type And Composition | 2 NC + 1 NO |
Contact Operation | Slow-break |
Trigger Cable Anchor Point | RH or LH side |
Connections - Terminals | Screw clamp terminal, 1 x 0.34...1 x 1 mm² Screw clamp terminal, 1 x 0.34...2 x 0.75 mm² |
Tightening Torque | 7.08…10.62 lbf.in (0.8…1.2 N.m) |
Cable Entry Number | 1 tapped entry ISO M20 cable gland |
Safety Level | Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Safety Reliability Data | B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5 |
Marking | CE |
Mechanical Durability | 100000 cycles |
Distance Btwn Cable Supports | 16.40 ft (5 m) |
Ie Rated Operational Current | 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A |
Ithe Cnvtl Enclosed Therm Crrt | 6 A |
Ui Rated Insulation Voltage | 400 V 3)EN/IEC 60947-1 300 VUL 508 300 VCSA C22.2 No 14 |
Uimp Rated Imp Wstd Voltage | 4 kV EN/IEC 60947-1 |
Positive Opening | With EN/IEC 60947-5-1 |
Resistance Across Terminals | 25 MOhm EN/IEC 60255-7 category 3 25 MOhm NF C 93-050 method A |
Short-Circuit Protection | 6 A cartridge fuse gG EN/IEC 60269 |
Terminals Description ISO n°1 | (31-32)NC (13-14)NO (21-22)NC |
Product Weight | 1.00 lb(US) (0.455 kg) |
Compatibility Code | XY2CJ |
Standards | Work equipment directive 2009/104/EC UL 508 EN/ISO 13850 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 60947-5-5 Machinery directive 2006/42/EC |
Product Certifications | UL category NISD emergency stop devices CSA CCC EAC |
Protective Treatment | TC |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Vibration Resistance | 10 gn 10…150 Hz)EN/IEC 60068-2-6 |
Shock Resistance | 50 gn 11 ms EN/IEC 60068-2-27 |
IP Degree Of Protection | IP66 IEC 60529 IP67 IEC 60529 |
Category | 22441 - LIMIT SWITCHES,CABLE PULL |
Discount Schedule | T |
GTIN | 03389119619554 |
Nbr. Of Units In Pkg. | 1 |
Country Of Origin | ID |
Green Premium Status | Green Premium product |
EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211