Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
E-stop rope pull switch XY2CJ – straight – 2NC+1NO – ISO M20
XY2CJS19H29
E-stop rope pull switch XY2CJ – straight – 2NC+1NO – ISO M20

This product is part of the XY2C range, an offer of emergency stop rope pull switches. This emergency stop rope pull switch has 2 normally closed + 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.1A at 250V AC, 1.5A at 240V AC and a conventional enclosed thermal current of 6A. It is furnished with screw clamp terminals for electrical connection and 1 tapped entry for ISO M20 cable gland. The trigger cable anchor point at left hand side. It can reset by booted pull button. It offers long mechanical durability which is about 100000 operating cycles. It is an IP66 and IP67 rated product. The casing is made of Zamak (red) with stainless steel cover. Its dimensions are 40mm (Width) x 64.2mm (Depth) x 201mm (Height) and weighs 0.455kg. It is intended for all machine applications like woodworking machines, shears, conveyor systems, printing machines, textile machines, rolling mills, test laboratories, paint shops, surface treatment works, etc. This product is certified by CCC, CSA and UL. It meets CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, UL 508 Machinery directive 2006/42/EC and Work equipment directive 2009/104/EC standards. These emergency stop rope pull switches can be equipped with trip indicators, cable tension adjustment can be performed using a turnbuckle. The emergency stop rope pull switch is intended for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. The emergency stop rope pull switch is designed to avert hazards (dangerous phenomena) at the earliest possible moment or to reduce risks which could cause injury to persons or damage either to machines or work in progress.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XY2CJS19H29
Country of Origin ID
UPC 389119619554
UPC11 38911961955
EAN 3389119619554
Availability N
Lead Time 55
UNSPSC 39122213
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator Yes
Weight 1.00 pound
Characteristics
Range Of Product Preventa XY2
Product Or Component Type Latching emergency stop rope pull switch
Device Short Name XY2C
Housing Colour Red RAL 3000
Overvoltage Category Class I EN/IEC 61140
Local Signalling Color indicator
Number Of Cables 1
Trigger Cable Maximum Length 65.62 ft (20 m)
Body Material Zamak
Head Material PA (polyamide)
Cover Material Galvanised steel
Reset By pull button
Contacts Type And Composition 2 NC + 1 NO
Contact Operation Slow-break
Trigger Cable Anchor Point RH or LH side
Connections - Terminals Screw clamp terminal, 1 x 0.34...1 x 1 mm² Screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
Tightening Torque 7.08…10.62 lbf.in (0.8…1.2 N.m)
Cable Entry Number 1 tapped entry ISO M20 cable gland
Safety Level Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Marking CE
Mechanical Durability 100000 cycles
Distance Btwn Cable Supports 16.40 ft (5 m)
Ie Rated Operational Current 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 6 A
Ui Rated Insulation Voltage 400 V 3)EN/IEC 60947-1 300 VUL 508 300 VCSA C22.2 No 14
Uimp Rated Imp Wstd Voltage 4 kV EN/IEC 60947-1
Positive Opening With EN/IEC 60947-5-1
Resistance Across Terminals 25 MOhm EN/IEC 60255-7 category 3 25 MOhm NF C 93-050 method A
Short-Circuit Protection 6 A cartridge fuse gG EN/IEC 60269
Terminals Description ISO n°1 (31-32)NC (13-14)NO (21-22)NC
Product Weight 1.00 lb(US) (0.455 kg)
Compatibility Code XY2CJ
Standards Work equipment directive 2009/104/EC UL 508 EN/ISO 13850 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 60947-5-5 Machinery directive 2006/42/EC
Product Certifications UL category NISD emergency stop devices CSA CCC EAC
Protective Treatment TC
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Vibration Resistance 10 gn 10…150 Hz)EN/IEC 60068-2-6
Shock Resistance 50 gn 11 ms EN/IEC 60068-2-27
IP Degree Of Protection IP66 IEC 60529 IP67 IEC 60529
Category 22441 - LIMIT SWITCHES,CABLE PULL
Discount Schedule T
GTIN 03389119619554
Nbr. Of Units In Pkg. 1
Country Of Origin ID
Green Premium Status Green Premium product
EU RoHs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury Free Yes
Documents
Royal Wholesale Electric

5.0

Powered by