Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
E-stop rope pull switch XY2CH – 1NC+1NO – booted pushbutton
XY2CH13250TK
E-stop rope pull switch XY2CH – 1NC+1NO – booted pushbutton
Specifications
Part Number XY2CH13250TK
Country of Origin MA
UPC 785901859963
UPC11 78590185996
EAN 3389110511888
Availability N
Lead Time 29
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Weight 1.91 pound
Characteristics
Range Of Product Preventa XY2
Product Or Component Type Latching emergency stop rope pull switch
Device Short Name XY2CH
Housing Colour Blue
Overvoltage Category Class I EN/IEC 61140 Class I NF C 20-030
Local Signalling Without pilot light
Number Of Cables 1
Trigger Cable Maximum Length 98.43 ft (30 m)
Body Material Zamak
Cover Material Stainless steel
Reset By booted push-button
Contacts Type And Composition 1 NC + 1 NO
Contact Operation Slow-break
Trigger Cable Anchor Point RH or LH side
Connections - Terminals Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Tightening Torque 7.08…10.62 lbf.in (0.8…1.2 N.m)
Cable Entry Number 3 tapped entry Pg 13.5 cable gland
Safety Level Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 4000000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Marking CE
Mechanical Durability 800000 cycles
Distance Btwn Cable Supports 16.40 ft (5 m)
Ie Rated Operational Current 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Ithe Cnvtl Enclosed Therm Crrt 10 A
Ui Rated Insulation Voltage 500 V 3)EN/IEC 60947-1 300 VUL 508
Uimp Rated Imp Wstd Voltage 6 kV EN/IEC 60947-1
Positive Opening With EN/IEC 60947-5-1
Resistance Across Terminals 25 MOhm EN/IEC 60255-7 category 3 25 MOhm NF C 93-050 method A
Short-Circuit Protection 10 A cartridge fuse gG EN/IEC 60269
Terminals Description ISO n°1 (13-14)NO (21-22)NC
Product Weight 1.91 lb(US) (0.865 kg)
Compatibility Code XY2CH
Environmental Characteristic Corrosive
Standards Machinery directive 2006/42/EC Work equipment directive 2009/104/EC EN/IEC 60947-5-5 EN/ISO 13850 EN/IEC 60947-5-1 EN/IEC 60204-1
Product Certifications UL category NISD emergency stop devices CCC
Protective Treatment TC
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…158 °F (-40…70 °C)
Vibration Resistance 10 gn 10…150 Hz)EN/IEC 60068-2-6
Shock Resistance 50 gn 11 ms EN/IEC 60068-2-27
IP Degree Of Protection IP65 IEC 60529
Category 22441 - LIMIT SWITCHES,CABLE PULL
Discount Schedule T
GTIN 00785901859963
Nbr. Of Units In Pkg. 1
Country Of Origin MA
Green Premium Status Green Premium product
EU RoHs Directive Pro-active compliance (Product out of EU RoHS legal scope)
Mercury Free Yes
Warranty 18 months
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews