| Part Number | 140DDO88500 |
|---|---|
| Country of Origin | CN |
| UPC | 785901103165 |
| UPC11 | 78590110316 |
| EAN | 3595861136069 |
| Availability | S |
| Lead Time | 43 |
| UNSPSC | 32151705 |
| ECCN | EAR99 |
| HTs Code | 8537109170 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | PC21 |
| Return Indicator | No |
| Weight | 0.99 pound |
| Range Of Product | Modicon Quantum automation platform |
|---|---|
| Product Or Component Type | Dc discrete output module |
| Discrete Output Number | 12 |
| Group Of Channels | 2 groups of 6 |
| Discrete Output Logic | Negative logic (sink) |
| Addressing Requirement | 1 input word 1 output word |
| Discrete Output Voltage | 24...125 V DC |
| Output Voltage Limits | 19.2...156.2 V |
| Maximum Load Current | <= 3 A 32…140 °F (0…60 °C) each group <= 6 A 32…140 °F (0…60 °C) per module <= 0.75 A 32…104 °F (0…40 °C) each point |
| Surge Current | 4 A 1 ms |
| Response Time | 1 ms at state 0 to state 1 1 ms at state 1 to state 0 |
| Short-Circuit Protection | With |
| Output Overvoltage Protct | By varistor per group |
| Load Inductance | No limit (protected by diode) |
| Tungsten Load | <41 W 115 V <46 W 130 V <8 W 24 V |
| Switching Frequency | <= 50 Hz |
| Fault Memory | Overcurrent |
| ISOl Betwn Channels And Bus | 2500 Vrms DC for 1 minute |
| ISOlation Between Group | 1200 Vrms DC for 1 minute |
| Protection Type | Internal output protection by 4 A fuse |
| Power Dissipation | 1 W + (0.77 x all points on) |
| Marking | CE |
| Local Signalling | Bus communication is present (Active) 1 LED green) External fault detected (F) 1 LED red) Input status 16 LEDs green) |
| Bus Current Requirement | 375 mA 6 outputs at state 1 650 mA 12 outputs at state 1 |
| Module Format | Standard |
| Product Weight | 0.99 lb(US) (0.45 kg) |
| Product Certifications | GOST FM Class 1 Division 2 C-tick RMRS |
| Standards | UL 508 CSA C22.2 No 142 |
| Resist Electrostatic Dischrg | 4 kV contact IEC 801-2 8 kV on air IEC 801-2 |
| Resist To Electromagn Fields | 9.14 V/m (10 V/m) 80…2000 MHz IEC 801-3 |
| Ambient Air Temp For Op | 32…140 °F (0…60 °C) |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
| Relative Humidity | 95 % without condensation |
| Operating Altitude | <= 16404.2 ft (5000 m) |
| Category | 18155 - QUANTUM I/O & POWER SUPPLIES |
| Discount Schedule | PC21 |
| GTIN | 00785901103165 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | CN |
| Green Premium Status | Green Premium product |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Warranty | 18 months |