Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Direct online SIL starter, TeSys island, 30A AC-1, 25A AC-3, 11kW / 15hp
TPRSS025
Direct online SIL starter, TeSys island, 30A AC-1, 25A AC-3, 11kW / 15hp

TeSys island direct SIL starter, 3 poles, 25A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 25A and motors up to 11kW@400V / 15hp@480V. In association with a TPRSM001 module and an external safety device, it can be used for safety related systems conforming to IEC 61508. It provides motor protection functions including thermal overload (setting 0.5-25A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number TPRSS025
UPC 606489832803
UPC11 60648983280
EAN 3606489832803
Availability N
Lead Time 30
ECCN EAR99
HTs Code 8536504000
RoHS Compliant Yes
Discount Schedule I12
Return Indicator Yes
Depth 4.53 inch
Height 4.76 inch
Width 1.77 inch
Weight 1.58 pound
Characteristics
Range TeSys
Product Name TeSys island
Device Short Name TPRSS
Product Or Component Type SIL motor starter
Motor Starter Type Direct on line
Device Presentation Direct starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler
Function Available Upstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module Safe stop function available when connected with a TPRSM module
Product Compatibility TPRBC bus coupler TPRVM voltage interface module TPRSM SIL interface module
Poles Description 3P 3 NO
Utilisation Category AC-1 AC-2 AC-3 AC-4
Motor Power kW 5.5 kW 230 V 50 Hz AC-3) 11 kW 380...415 V 50 Hz AC-3) 11 kW 440 V 50 Hz AC-3) 15 kW 500 V 50 Hz AC-3) 15 kW 690 V 50 Hz AC-3)
Motor Power Hp (Ul / Csa) 2 hp 120 V AC 60 Hz 1 phase 3 hp 240 V AC 60 Hz 1 phase 7.5 hp 208 V AC 60 Hz 3 phase 7.5 hp 240 V AC 60 Hz 3 phase 15 hp 480 V AC 60 Hz 3 phase 20 hp 600 V AC 60 Hz 3 phase
Ue Rated Operational Voltage <= 480 V AC 47...63 Hz <= 690 V AC 47...63 Hz
Ie Rated Operational Current 25 A 122 °F (50 °C)) <= 440 V AC-3 30 A 122 °F (50 °C)) <= 440 V AC-1
Ith Cnvtl Free Air Therm Crrt 30 A 122 °F (50 °C)
Ui Rated Insulation Voltage 690 V IEC 60947-4-1 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947-1
Overvoltage Category III II
Thermal Protection Adj Range 0.5…25 A
Thermal Overload Class Class 5…30
Reset Remotely or automatically
Irms Rated Making Capacity 450 A 440 V IEC 60947
Rated Breaking Capacity 450 A 440 V IEC 60947
Icw Rated Short-Time Wstd Crrt 380 A 104 °F (40 °C) - 1 s 240 A 104 °F (40 °C) - 10 s 120 A 104 °F (40 °C) - 1 min 50 A 104 °F (40 °C) - 10 min
Average Impedance 2 mOhm - Ith 30 A 50 Hz
Power Dissipation Per Pole 1.25 W AC-3 - Ith 25 A 1.8 W AC-1 - Ith 30 A
Uc Control Circuit Voltage 24 V DC supplied by the bus coupler
Current Consumption 160 mA contactor sealed 160 mA contactor closing
Power Dissipation In W 6.6 W at Ie
Mechanical Durability 30 Mcycles
Electrical Durability 1.65 Mcycles 25 A AC-3 440 V 2 Mcycles 30 A AC-1 440 V
Operating Rate 3600 cyc/mn AC-3
Operating Time < 100 ms closing < 30 ms opening
Safety Function Safe stop IEC 60204-1 Safe stop IEC 60204-1
Safety Integrity Level SIL 2 IEC 61508 SILCL 2 IEC 62061 PL = d ISO 13849-1
Safety Performance Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Protection Type Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Phase sequence Rapid restart lockout Phase reversal Phase loss Phase unbalance Ground current
Monitoring Type Time device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module
Local Signalling DS (device status) 1 LED green/red) LS (load status) 1 LED green/red)
Standards EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Product Certifications CCC EAC UL CSA
Mounting Mode Horizontal and vertical 35 mm symmetrical DIN rail)
Connections - Terminals screw-clamp terminals 1 0.00…0.02 in² (1.5…10 mm²) AWG 16...AWG 8)rigid screw-clamp terminals 2 0.00…0.02 in² (1.5…10 mm²) AWG 16...AWG 8)rigid screw-clamp terminals 1 0.00…0.02 in² (2.5…10 mm²) AWG 14...AWG 8)flexible without cable end screw-clamp terminals 2 0.00…0.02 in² (2.5…10 mm²) AWG 14...AWG 8)flexible without cable end screw-clamp terminals 1 0.00…0.02 in² (1.5…10 mm²) AWG 16...AWG 10)flexible with cable end screw-clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) AWG 16...AWG 10)flexible with cable end
Tightening Torque 22.13 lbf.in (2.5 N.m) flat Ø 6 mm 22.13 lbf.in (2.5 N.m) Philips No 3
Width 1.77 in (45 mm)
Height 4.76 in (121 mm)
Depth 4.53 in (115 mm)
Product Weight 1.58 lb(US) (0.718 kg)
Ambient Air Temp For Storage -13…158 °F (-25…70 °C)
Ambient Air Temp For Op 14…122 °F (-10…50 °C) without derating 122…140 °F (50…60 °C) with current derating
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews