This Zelio RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC.
Add to Quote CataloguePart Number | RM35JA32MR |
---|---|
Country of Origin | ID |
UPC | 785901069362 |
UPC11 | 78590106936 |
EAN | 3606480792304 |
Availability | N |
Lead Time | 24 |
UNSPSC | 39122329 |
HTs Code | 8536490075 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | CP2 |
Return Indicator | Yes |
Width | 1.38 inch |
Weight | 0.26 pound |
Range Of Product | Zelio Control |
---|---|
Product Or Component Type | Modular measurement and control relays |
Relay Type | Current control relay |
Relay Name | RM35JA |
Relay Monitored Parameters | Overcurrent or undercurrent in window mode Overcurrent or undercurrent detection |
Time Delay Type | Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt |
Switching Capacity In Va | 2000 VA |
Measurement Range | 0.15...1.5 A E1-M terminals 0.5...5 A E2-M terminals 1.5...15 A E3-M terminals 150 mA...15 A current AC/DC 50/60 Hz |
Reset Time | 1500 ms at maximum voltage |
Maximum Switching Voltage | 250 V AC |
Minimum Switching Current | 10 mA 5 V DC |
Maximum Switching Current | 8 A AC |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz +/- 10 % |
Supply Voltage Limits | 20.4…264 V AC/DC |
Operating Limits | 15 % + 10 % Un |
Power Consumption In Va | 3.5 VA AC |
Power Consumption In W | 1.5 W DC |
Resistance Across Terminals | 0.005 Ohm E3-M terminals 0.015 Ohm E2-M terminals 0.05 Ohm E1-M terminals |
Output Contacts | 2 C/O |
Nominal Output Current | 8 A |
Internal Input Resistance | 0.015 Ohm 0.005 Ohm 0.05 Ohm |
Setg Accr Of The Swting Thrhld | +/- 10 % of the full scale |
Switching Threshold Drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range |
Setting Accuracy Of Time Delay | 10 % |
Time Delay Drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range |
Hysteresis | 5…50 % adjustable threshold setting overcurrent or undercurrent detection 3 % fixed full scale for window mode |
Run-Up Delay At Power-Up | 0.3 s |
Measuring Cycle | 100 ms measurement cycle as true rms value |
Repeat Accuracy | +/- 0.5 % input and measurement circuit +/- 2 % time delay |
Measurement Error | < 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation |
Response Time | <= 500 ms on crossing the threshold) |
Threshold Setting | 10...100 % |
Overvoltage Category | III IEC 60664-1 III UL 508 |
Insulation Resistance | > 100 MOhm 500 V DC IEC 60255-27 |
Insulation | Between supply and measurement |
Mounting Position | Any position |
Connections - Terminals | Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end |
Tightening Torque | 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1 |
Housing Material | Self-extinguishing plastic |
Status Led | Relay ON LED Yellow) Power ON LED Green) |
Mounting Support | 35 mm DIN rail EN/IEC 60715 |
Electrical Durability | 100000 cycles |
Mechanical Durability | 10000000 cycles |
Utilisation Category | AC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1 |
Safety Reliability Data | MTTFd = 296.8 years B10d = 270000 |
Contacts Material | Cadmium free |
Width | 1.38 in (35 mm) |
Product Weight | 0.26 lb(US) (0.12 kg) |
Immunity To Microbreaks | 50 ms |
Electromagnetic Compatibility | Immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 Immunity for industrial environments EN/IEC 61000-6-2 Emission standard for industrial environments EN/IEC 61000-6-4 Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 Surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 Surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 Conducted and radiated emissionsclass B group 1 CISPR 11 Conducted and radiated emissionsclass B CISPR 22 Emission standard for residential, commercial and light-industrial environments except radiated emission) EN/IEC 61000-6-3 |