| Part Number | LC1K09008B7TQ |
|---|---|
| Country of Origin | FR |
| UPC | 389110488777 |
| UPC11 | 38911048877 |
| EAN | 3389110488777 |
| Availability | N |
| Lead Time | 20 |
| UNSPSC | 39121529 |
| ECCN | EAR99 |
| HTs Code | 8536490065 |
| Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | No |
| Depth | 2.24 inch |
| Height | 2.28 inch |
| Width | 1.77 inch |
| Weight | 0.40 pound |
| Product Or Component Type | Contactor |
|---|---|
| Device Short Name | LC1K |
| Contactor Application | Resistive load |
| Utilisation Category | AC-1 |
| Poles Description | 4P |
| Power Pole Contact Composition | 2 NO + 2 NC |
| Ue Rated Operational Voltage | Power circuit <= 690 V AC <= 400 Hz |
| Ie Rated Operational Current | 20 A 122 °F (50 °C)) AC AC-1 power circuit |
| Auxiliary Contact Composition | 2 NO + 2 NC |
| Uimp Rated Imp Wstd Voltage | 8 kV |
| Ith Cnvtl Free Air Therm Crrt | 10 A 122 °F (50 °C) control circuit 20 A 122 °F (50 °C) power circuit |
| Irms Rated Making Capacity | 110 A 690 V AC control circuit IEC 60947 110 A 690 V AC power circuit IEC 60947 110 A 690 V AC power circuit NF C 63-110 |
| Rated Breaking Capacity | 110 A 440 V power circuit IEC 60947 110 A 440 V power circuit NF C 63-110 70 A 660...690 V power circuit IEC 60947 70 A 660...690 V power circuit NF C 63-110 80 A 500 V power circuit IEC 60947 80 A 500 V power circuit NF C 63-110 110 A 220...230 V power circuit IEC 60947 110 A 220...230 V power circuit NF C 63-110 110 A 380...400 V power circuit IEC 60947 110 A 380...400 V power circuit NF C 63-110 110 A 415 V power circuit IEC 60947 110 A 415 V power circuit NF C 63-110 |
| Associated Fuse Rating | 10 A gG control circuit IEC 60947 10 A gG control circuit VDE 0660 25 A gG <= 440 V power circuit |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz power circuit |
| Ui Rated Insulation Voltage | Control circuit 690 V BS 5424 Control circuit 690 V IEC 60947 Power circuit 690 V BS 5424 Power circuit 690 V IEC 60947 Power circuit 690 V NF C 20-040 Control circuit 750 V VDE 0110 group C Power circuit 750 V VDE 0110 group C Control circuit 600 V CSA C22.2 No 14 Power circuit 600 V UL 508 CSA C22.2 No 14 |
| Insulation Resistance | > 10 MOhm control circuit |
| Inrush Power In VA | 30 VA 68 °F (20 °C)) |
| Hold-In Power Consumption Va | 4.5 VA 50/60 Hz 68 °F (20 °C)) |
| Ctrl Circuit Voltage Limits | Drop-out >= 0.20 Uc 50/60 Hz 122 °F (50 °C)) Operational 0.8...1.15 Uc 50/60 Hz 122 °F (50 °C)) |
| Operating Rate | 3600 cyc/h |
| Coil Technology | Without built-in bidirectional peak limiting diode suppressor |
| Minimum Switching Current | 5 mA control circuit |
| Minimum Switching Voltage | 17 V control circuit |
| Mounting Support | Rail Plate |
| Operating Time | 10...20 ms coil de-energisation and NO opening 15...25 ms coil de-energisation and NC opening 10...20 ms between energisation of coil and closing of NO contact 5...15 ms coil energisation and NC opening |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical Durability | 10000000 cycles |
| Height | 2.28 in (58 mm) |
| Width | 1.77 in (45 mm) |
| Depth | 2.24 in (57 mm) |
| Product Weight | 0.40 lb(US) (0.18 kg) |
| Product Certifications | GOST CSA UL |
| Ambient Air Temp For Storage | -58…176 °F (-50…80 °C) |
| Operating Altitude | 6561.68 ft (2000 m) without derating |
| Fire Resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame Retardance | Class C2 NF F 16-101 Class C2 NF F 16-102 V1 UL 94 |
| Category | 22326 - CTR,K-LINE,AC,OPEN,NONREV |
| Discount Schedule | I12 |
| GTIN | 03389110488777 |
| Nbr. Of Units In Pkg. | 30 |
| Country Of Origin | FR |
| Green Premium Status | Green Premium product |
| REACh Free Of SVHC | Yes |
| EU RoHs Directive | Compliant |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Warranty | 18 months |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366