Specifications
Part Number LC1D40AG7TQ
Country of Origin FR
UPC 389118346765
UPC11 38911834676
EAN 3389118346765
Availability N
Lead Time 20
UNSPSC 39121529
ECCN EAR99
HTs Code 8536490065
Prop 65 This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule I12
Return Indicator No
Depth 4.72 inch
Height 4.80 inch
Width 2.17 inch
Weight 3.09 pound
Characteristics
Range Of Product TeSys D
Range TeSys
Product Or Component Type Contactor
Device Short Name LC1D
Contactor Application Motor control Resistive load
Utilisation Category AC-3 AC-2 AC-1 AC-4
Control Circuit Type AC 60 Hz
Poles Description 3P
Pole Contact Composition 3 NO
Ie Rated Operational Current 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
Motor Power kW 18.5 kW 380...400 V AC 50 Hz AC-3) 22 kW 500 V AC 50 Hz AC-3) 30 kW 660...690 V AC 50 Hz AC-3) 11 kW 220...230 V AC 50 Hz AC-3) 9 kW 400 V AC 50 Hz AC-4) 22 kW 415...440 V AC 50 Hz AC-3)
Quantity Per Set Set of 10
Coil Technology Without built-in bidirectional peak limiting diode suppressor
Front Cover With
Motor Power Hp 3 hp 115 V AC 60 Hz 1 phase 5 hp 230/240 V AC 60 Hz 1 phase 10 hp 200/208 V AC 60 Hz 3 phase 10 hp 230/240 V AC 60 Hz 3 phase 30 hp 460/480 V AC 60 Hz 3 phase 30 hp 575/600 V AC 60 Hz 3 phase
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition 1 NO + 1 NC
Uc Control Circuit Voltage 120 V AC 60 Hz
Ctrl Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 60 Hz
Ui Rated Insulation Voltage Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-1 Power circuit 690 V IEC 60947-1
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947
Overvoltage Category III
Mounting Support Plate Rail
Flame Retardance V1 UL 94
Connections - Terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)rigid Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)rigid Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)rigid Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)rigid Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible with cable end
Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2 Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hex (Allen key) 0.16 in (4 mm) Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.05 in² (35 mm²) hex (Allen key) 0.16 in (4 mm)
Ue Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz
Ith Cnvtl Free Air Therm Crrt 10 A 140 °F (60 °C) control circuit 60 A 140 °F (60 °C) power circuit
Irms Rated Making Capacity 800 A 440 V power circuit IEC 60947 140 A AC control circuit IEC 60947-5-1
Rated Breaking Capacity 800 A 440 V power circuit IEC 60947
Associated Fuse Rating 10 A gG control circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
Power Dissipation Per Pole 5.4 W AC-1 2.4 W AC-3
Inrush Power In VA 140 VA 0.75 68 °F (20 °C)) 160 VA 0.75 68 °F (20 °C))
Hold-In Power Consumption Va 13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C))
Operating Time 4...19 ms opening 12...26 ms closing
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability 6000000 cycles
Operating Rate 3600 cyc/h 140 °F (60 °C)
Minimum Switching Current 5 mA control circuit
Minimum Switching Voltage 17 V control circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts
Insulation Resistance > 10 MOhm control circuit
Height 4.80 in (122 mm)
Width 2.17 in (55 mm)
Depth 4.72 in (120 mm)
Product Weight 3.09 lb(US) (1.4 kg)
Compatibility Code LC1D
Standards EN 60947-5-1 CSA C22.2 No 14 UL 508 IEC 60947-4-1 IEC 60947-5-1 EN 60947-4-1
Product Certifications GL CCC GOST LROS (pending) RINA UL CSA BV DNV
IP Degree Of Protection IP2x IEC 60529 IP2x VDE 0106