Part Number | LC1D40AG7TQ |
---|---|
Country of Origin | FR |
UPC | 389118346765 |
UPC11 | 38911834676 |
EAN | 3389118346765 |
Availability | N |
Lead Time | 20 |
UNSPSC | 39121529 |
ECCN | EAR99 |
HTs Code | 8536490065 |
Prop 65 | This product can expose you to chemicals including: Antimony oxide & Antimony trioxide which is known to the State of California to cause Carcinogen harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | I12 |
Return Indicator | No |
Depth | 4.72 inch |
Height | 4.80 inch |
Width | 2.17 inch |
Weight | 3.09 pound |
Range Of Product | TeSys D |
---|---|
Range | TeSys |
Product Or Component Type | Contactor |
Device Short Name | LC1D |
Contactor Application | Motor control Resistive load |
Utilisation Category | AC-3 AC-2 AC-1 AC-4 |
Control Circuit Type | AC 60 Hz |
Poles Description | 3P |
Pole Contact Composition | 3 NO |
Ie Rated Operational Current | 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit |
Motor Power kW | 18.5 kW 380...400 V AC 50 Hz AC-3) 22 kW 500 V AC 50 Hz AC-3) 30 kW 660...690 V AC 50 Hz AC-3) 11 kW 220...230 V AC 50 Hz AC-3) 9 kW 400 V AC 50 Hz AC-4) 22 kW 415...440 V AC 50 Hz AC-3) |
Quantity Per Set | Set of 10 |
Coil Technology | Without built-in bidirectional peak limiting diode suppressor |
Front Cover | With |
Motor Power Hp | 3 hp 115 V AC 60 Hz 1 phase 5 hp 230/240 V AC 60 Hz 1 phase 10 hp 200/208 V AC 60 Hz 3 phase 10 hp 230/240 V AC 60 Hz 3 phase 30 hp 460/480 V AC 60 Hz 3 phase 30 hp 575/600 V AC 60 Hz 3 phase |
Auxiliary Contacts Type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Uc Control Circuit Voltage | 120 V AC 60 Hz |
Ctrl Circuit Voltage Limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 60 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 60 Hz |
Ui Rated Insulation Voltage | Control circuit 600 V CSA Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL Control circuit 690 V IEC 60947-1 Power circuit 690 V IEC 60947-1 |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947 |
Overvoltage Category | III |
Mounting Support | Plate Rail |
Flame Retardance | V1 UL 94 |
Connections - Terminals | Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)rigid Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)rigid Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)rigid Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)rigid Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.00…0.05 in² (1…35 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 2 0.00…0.04 in² (1…25 mm²)flexible with cable end |
Tightening Torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminal Philips No 2 Power circuit 44.25 lbf.in (5 N.m) EverLink BTR screw connectors 0.00…0.04 in² (1…25 mm²) hex (Allen key) 0.16 in (4 mm) Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.05 in² (35 mm²) hex (Allen key) 0.16 in (4 mm) |
Ue Rated Operational Voltage | Power circuit <= 690 V AC 25...400 Hz |
Ith Cnvtl Free Air Therm Crrt | 10 A 140 °F (60 °C) control circuit 60 A 140 °F (60 °C) power circuit |
Irms Rated Making Capacity | 800 A 440 V power circuit IEC 60947 140 A AC control circuit IEC 60947-5-1 |
Rated Breaking Capacity | 800 A 440 V power circuit IEC 60947 |
Associated Fuse Rating | 10 A gG control circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit |
Power Dissipation Per Pole | 5.4 W AC-1 2.4 W AC-3 |
Inrush Power In VA | 140 VA 0.75 68 °F (20 °C)) 160 VA 0.75 68 °F (20 °C)) |
Hold-In Power Consumption Va | 13 VA 60 Hz 0.3 68 °F (20 °C)) 15 VA 50 Hz 0.3 68 °F (20 °C)) |
Operating Time | 4...19 ms opening 12...26 ms closing |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Mechanical Durability | 6000000 cycles |
Operating Rate | 3600 cyc/h 140 °F (60 °C) |
Minimum Switching Current | 5 mA control circuit |
Minimum Switching Voltage | 17 V control circuit |
Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts |
Insulation Resistance | > 10 MOhm control circuit |
Height | 4.80 in (122 mm) |
Width | 2.17 in (55 mm) |
Depth | 4.72 in (120 mm) |
Product Weight | 3.09 lb(US) (1.4 kg) |
Compatibility Code | LC1D |
Standards | EN 60947-5-1 CSA C22.2 No 14 UL 508 IEC 60947-4-1 IEC 60947-5-1 EN 60947-4-1 |
Product Certifications | GL CCC GOST LROS (pending) RINA UL CSA BV DNV |
IP Degree Of Protection | IP2x IEC 60529 IP2x VDE 0106 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366