The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. It is a coded magnetic system with dedicated transmitter. 9 approach directions. This self-contained system does not require the use of a safety module or non-magnetic shim. It features a rectangular plastic boby, and a 2m long pre-cabled electrical connection . It has a solid-state PNP type output. It can reach SIL 3, with the appropriate monitoring system and correctly wired, conforming to EN/IEC 61508.
Brand: Telemecanique
Add to Quote Catalogue| Part Number | XCSDM480102 |
|---|---|
| Country of Origin | FR |
| UPC | 785901620891 |
| UPC11 | 78590162089 |
| EAN | 3389118307308 |
| Availability | N |
| Lead Time | 38 |
| UNSPSC | 39122213 |
| ECCN | EAR99 |
| HTs Code | 8536509055 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | T |
| Return Indicator | No |
| Depth | 1.26 inch |
| Height | 3.94 inch |
| Width | 1.34 inch |
| Weight | 0.71 pound |
| Range Of Product | Preventa Safety detection |
|---|---|
| Product Or Component Type | Coded magnetic system |
| Component Name | XCSDM4 |
| Design | Rectangular |
| Size | 100 x 34 x 32 mm |
| Contacts Type And Composition | 1 NO + 1 NO |
| Material | Plastic |
| Electrical Connection | Pre-cabled |
| Cable Composition | 8 x 0.25 mm |
| Cable Length | 6.56 ft (2 m) |
| Ohmic Cable Resistance | 180 mOhm |
| Local Signalling | Green, orange and red 1 LED |
| Approach Directions | 9 directions |
| Ue Rated Operational Voltage | 24 V DC - 20...10 %) |
| Ui Rated Insulation Voltage | 36 V DC |
| Cable Outer Diameter | 0.24 in (6.1 mm) |
| Type Of Output Stage | Solid-state, PNP |
| Safety Outputs | 2 outputs 1.5 A, 24 V, DC |
| Alarm Output | 1 solid-state output, 0.5 A, 24 V, DC, PNP |
| Sa Assured Operating Distance | 0.39 in (10 mm) |
| [Sar]Assured Tripping Distance | 0.79 in (20 mm) |
| Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
| Uimp Rated Imp Wstd Voltage | 2.5 kV EN/IEC 60947-5-1 |
| Protection Type | Overload and short-circuit protection |
| Switching Frequency | 3 Hz |
| Time Delay | 100 ms activation |
| Discordance Time | 2 s |
| [Hft] Hardware Fault Tolerance | 1 |
| Tightening Torque | < 1.8 N.m |
| Installed Device | 32 maximum with 2 m long cable |
| Marking | CE |
| Safety Level | Category 4 correctly wired EN/ISO 13849-1 PL = e correctly wired EN/ISO 13849-1 SIL 3 correctly wired EN/IEC 61508 |
| Safety Reliability Data | HFT = 1 MTTFd = 182 years PFD = 1.15E-5 PFH = 3.94E-9 SF = 92.5 % |
| Enclosure Material | Thermoplastic PBT |
| Cable Material | PVC |
| Depth | 1.26 in (32 mm) |
| Height | 3.94 in (100 mm) |
| Width | 1.34 in (34 mm) |
| Product Weight | 0.71 lb(US) (0.32 kg) |
| Standards | EN/IEC 60947-5-2 ISO 14119 EN/IEC 62061 EN 13849-1 EN/IEC 60947-5-1 IEC 61508 EN/IEC 60947-5-3 |
| Product Certifications | TÜV UL CSA |
| Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
| Vibration Resistance | 10 gn 10…500 Hz)IEC 60068-2-6 |
| Shock Resistance | 30 gn 11 ms IEC 60068-2-27 |
| Sensitivity To Magnetic Fields | 0.5 mT |
| Electrical Shock Protect Class | Class III EN/IEC 61140 |
| IP Degree Of Protection | IP66 IEC 60529 IP67 IEC 60529 IP69K DIN 40050 |
| Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
| Discount Schedule | T |