The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. It is a coded magnetic system with dedicated transmitter. 9 approach directions. This self-contained system does not require the use of a safety module or non-magnetic shim. It features a rectangular plastic boby, and a 2m long pre-cabled electrical connection . It has a solid-state PNP type output. It can reach SIL 2/PL equal d, category 3, with the appropriate monitoring system and correctly wired.
Brand: Telemecanique
Add to Quote CataloguePart Number | XCSDM379102 |
---|---|
Country of Origin | FR |
UPC | 785901661504 |
UPC11 | 78590166150 |
EAN | 3389118307278 |
Availability | S |
Lead Time | 3 |
UNSPSC | 39122213 |
ECCN | EAR99 |
HTs Code | 8536509065 |
Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Discount Schedule | T |
Return Indicator | Yes |
Depth | 1.26 inch |
Height | 3.94 inch |
Width | 1.34 inch |
Weight | 0.71 pound |
Range Of Product | Preventa Safety detection |
---|---|
Product Or Component Type | Coded magnetic system |
Component Name | XCSDM3 |
Design | Rectangular |
Size | 100 x 34 x 32 mm |
Contacts Type And Composition | 1 NO + 1 NO |
Material | Plastic |
Electrical Connection | Pre-cabled |
Cable Composition | 6 x 0.25 mm² |
Cable Length | 6.56 ft (2 m) |
Ohmic Cable Resistance | 180 mOhm |
Local Signalling | Green, orange and red 1 LED |
Approach Directions | 9 directions |
Ue Rated Operational Voltage | 24 V DC - 20...10 %) |
Ui Rated Insulation Voltage | 36 V DC |
Cable Outer Diameter | 0.24 in (6.1 mm) |
Type Of Output Stage | Solid-state, PNP |
Safety Outputs | 2 outputs 1.5 A, 24 V, DC |
Sa Assured Operating Distance | 0.39 in (10 mm) |
[Sar]Assured Tripping Distance | 0.79 in (20 mm) |
Minimum Actuation Speed | 0.03 ft/s (0.01 m/s) |
Uimp Rated Imp Wstd Voltage | 2.5 kV EN/IEC 60947-5-1 |
Protection Type | Overload and short-circuit protection |
Switching Frequency | 3 Hz |
Time Delay | 100 ms activation |
Discordance Time | 2 s |
[Hft] Hardware Fault Tolerance | 1 |
Tightening Torque | < 1.8 N.m |
Installed Device | 32 maximum with 2 m long cable |
Marking | CE |
Safety Level | Can reach category 3 correctly wired EN/ISO 13849-1 Can reach PL = d correctly wired EN/ISO 13849-1 Can reach SIL 2 correctly wired EN/IEC 61508 |
Safety Reliability Data | HFT = 1 MTTFd = 182 years PFD = 1.15E-5 PFH = 3.94E-9 SF = 92.5 % |
Enclosure Material | Thermoplastic PBT |
Cable Material | PVC |
Depth | 1.26 in (32 mm) |
Height | 3.94 in (100 mm) |
Width | 1.34 in (34 mm) |
Product Weight | 0.71 lb(US) (0.32 kg) |
Standards | EN/IEC 60947-5-2 IEC 61508 EN/IEC 60947-5-1 EN 13849-1 ISO 14119 EN/IEC 62061 EN/IEC 60947-5-3 |
Product Certifications | TÜV CSA UL |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Vibration Resistance | 10 gn 10…500 Hz)IEC 60068-2-6 |
Shock Resistance | 30 gn 11 ms IEC 60068-2-27 |
Sensitivity To Magnetic Fields | 0.5 mT |
Electrical Shock Protect Class | Class III EN/IEC 61140 |
IP Degree Of Protection | IP66 IEC 60529 IP67 IEC 60529 IP69K DIN 40050 |
Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
Discount Schedule | T |
GTIN | 00785901661504 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366