The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. This coded magnetic system, detects without contact. 3 approach directions. It features a rectangular plastic boby, 88mm x 25mm x 13mm, and a 10m long pre-cabled electrical connection . 3-pole contact 1 NC + 2 NO (1 NO staggered). It can reach category 4 Safety Level with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1. It can reach PL equal e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1. It can reach SIL 3, with the appropriate monitoring system and correctly wired, conforming to EN/IEC 61508.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XCSDMP50110
Country of Origin FR
UPC 389110971972
UPC11 38911097197
EAN 3389110971972
Availability N
Lead Time 35
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator No
Depth 0.51 inch
Height 3.46 inch
Width 0.98 inch
Weight 0.40 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Coded magnetic switch
Component Name XCSDMP
Design Rectangular, standard
Size 88 x 25 x 13 mm
Contacts Type And Composition 1 NC + 2 NO
Contact Operation 1 NO staggered
Material Plastic
Electrical Connection Pre-cabled
Cable Composition 6 x 0.25 mm²
Cable Length 32.81 ft (10 m)
Number Of Poles 3
Local Signalling 1 LED
Approach Directions 3 directions
Ue Rated Operational Voltage 24 V DC
Ui Rated Insulation Voltage 100 V DC
Sa Assured Operating Distance 0.31 in (8 mm)
[Sar]Assured Tripping Distance 0.79 in (20 mm)
Ie Rated Operational Current 100 mA
Uimp Rated Imp Wstd Voltage 2.5 kV EN/IEC 60947-5-1
Resistance Across Terminals 57 Ohm
Short-Circuit Protection 500 mA external cartridge fuse gG (gl)
Contacts Material Rhodium
Electrical Durability 1200000 cycles
Maximum Switching Voltage 100 V DC
Switching Capacity In Ma 5...100 mA
Insulation Resistance 1000 MOhm
Breaking Capacity 3 VA
Switching Frequency 150 Hz
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material Thermoplastic PBT
Cable Material PVC
Depth 0.51 in (13 mm)
Height 3.46 in (88 mm)
Width 0.98 in (25 mm)
Product Weight 0.40 lb(US) (0.18 kg)
Standards CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508 EN/IEC 60204-1 EN/ISO 12100 ISO 14119
Product Certifications UL BG CSA
Protective Treatment TH
Ambient Air Temp For Op -13…185 °F (-25…85 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
Vibration Resistance 10 gn 10…150 Hz)IEC 60068-2-6
Shock Resistance 30 gn 11 ms IEC 60068-2-27
Sensitivity To Magnetic Fields 0.3 mT
Electrical Shock Protect Class Class II EN/IEC 61140
IP Degree Of Protection IP66 IEC 60529 IP67 IEC 60529
Category 22411 - LIMIT SWITCHES,IEC,XCKJ
Discount Schedule T
GTIN 03389110971972