| Part Number | XCSDMC59030EX |
|---|---|
| Country of Origin | FR |
| UPC | 389119048279 |
| UPC11 | 38911904827 |
| EAN | 3389119048279 |
| Availability | N |
| Lead Time | 27 |
| ECCN | EAR99 |
| HTs Code | 8536509055 |
| Prop 65 | This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | T |
| Return Indicator | No |
| Weight | 0.22 pound |
| Range Of Product | Preventa ATEX D |
|---|---|
| Product Or Component Type | Coded magnetic switch |
| Device Short Name | XCSDMC |
| Material | Plastic |
| Contacts Type And Composition | 1 NC + 1 NO |
| Contact Operation | Staggered |
| Electrical Connection | Pre-cabled |
| Cable Composition | 4 x 0.25 mm² |
| Cable Length | 98.43 ft (30 m) |
| Design | Rectangular, compact |
| Size | 51 x 16 x 7 mm |
| Number Of Poles | 2 |
| Sa Assured Operating Distance | 0.20 in (5 mm) |
| [Sar]Assured Tripping Distance | 0.59 in (15 mm) |
| Approach Directions | 3 directions |
| Ue Rated Operational Voltage | 24 V DC |
| Ie Rated Operational Current | 100 mA |
| Ui Rated Insulation Voltage | 100 V DC |
| Uimp Rated Imp Wstd Voltage | 2.5 kV EN/IEC 60947-5-1 |
| Resistance Across Terminals | 10 Ohm |
| Short-Circuit Protection | 500 mA external cartridge fuse gG (gl) |
| Contacts Material | Rhodium |
| Electrical Durability | 1200000 cycles |
| Maximum Switching Voltage | 100 V DC |
| Switching Capacity In Ma | 0.1...100 mA |
| Insulation Resistance | 1000 MOhm |
| Breaking Capacity | 10 VA |
| Switching Frequency | 150 Hz |
| Product Weight | 0.22 lb(US) (0.101 kg) |
| Safety Level | Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508 |
| Safety Reliability Data | B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear |
| Protective Treatment | TH |
| Ambient Air Temp For Op | -13…185 °F (-25…85 °C) |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
| Vibration Resistance | 10 gn 10…150 Hz)IEC 60068-2-6 |
| Shock Resistance | 30 gn 11 ms IEC 60068-2-27 |
| Sensitivity To Magnetic Fields | 0.3 mT |
| Electrical Shock Protect Class | Class II IEC 60536 |
| IP Degree Of Protection | IP66 IEC 60529 IP67 IEC 60529 |
| Enclosure Material | Thermoplastic PBT |
| Cable Material | PVC |
| Dust Zone | According to protection mode mD, tD and ia Zone 0 - 1 - 2/20 - 21 - 22 |
| Product Certifications | INERIS 04ATEX0036 |
| Standards | EN 60079-0 EN 60079-11 EN 60079-18 EN 60079-31 EN/ISO 13849-1 |
| Directives | 2014/34/EU - ATEX directive |
| Category | 22411 - LIMIT SWITCHES,IEC,XCKJ |
| Discount Schedule | T |
| GTIN | 03389119048279 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | FR |