Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Coded magnetic switch XCSDMC – 2 NC – staggered – 5m
XCSDMC7905
Coded magnetic switch XCSDMC – 2 NC – staggered – 5m

The Preventa XCS range is an offer of safety switches. They are designed for controlling the safe opening and interlocking of guards and covers. This coded magnetic switch is dedicated to detection without contact. 3 approach directions. It features a rectangular plastic boby, and 5m long pre-cable electrical connection . It has 2 NC staggered contacts. It can reach category 4 Safety Level with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1. It can reach PL equal e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 It can reach SIL 3, with the appropriate monitoring system and correctly wired, conforming to EN/IEC 61508.

Brand: Telemecanique

Add to Quote Catalogue
Specifications
Part Number XCSDMC7905
Country of Origin FR
UPC 389110971736
UPC11 38911097173
EAN 3389110971736
Availability N
Lead Time 33
UNSPSC 39122213
ECCN EAR99
HTs Code 8536509065
Prop 65 This product can expose you to chemicals including: Di-isodecyl phthalate (DIDP) and Diisononyl phthalate (DINP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Discount Schedule T
Return Indicator Yes
Depth 0.28 inch
Height 2.01 inch
Width 0.63 inch
Weight 0.22 pound
Characteristics
Range Of Product Preventa Safety detection
Product Or Component Type Coded magnetic switch
Component Name XCSDMC
Design Rectangular, compact
Size 51 x 16 x 7 mm
Contacts Type And Composition 2 NC
Contact Operation Staggered
Material Plastic
Electrical Connection Pre-cabled
Cable Composition 4 x 0.25 mm²
Cable Length 16.40 ft (5 m)
Number Of Poles 2
Approach Directions 3 directions
Ue Rated Operational Voltage 24 V DC
Ui Rated Insulation Voltage 100 V DC
Sa Assured Operating Distance 0.20 in (5 mm)
[Sar]Assured Tripping Distance 0.59 in (15 mm)
Ie Rated Operational Current 100 mA
Uimp Rated Imp Wstd Voltage 2.5 kV EN/IEC 60947-5-1
Resistance Across Terminals 10 Ohm
Short-Circuit Protection 500 mA external cartridge fuse gG (gl)
Contacts Material Rhodium
Electrical Durability 1200000 cycles
Maximum Switching Voltage 100 V DC
Switching Capacity In Ma 0.1...100 mA
Insulation Resistance 1000 MOhm
Breaking Capacity 10 VA
Switching Frequency 150 Hz
Safety Level Can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Safety Reliability Data B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Material Thermoplastic PBT
Cable Material PVC
Depth 0.28 in (7 mm)
Height 2.01 in (51 mm)
Width 0.63 in (16 mm)
Product Weight 0.22 lb(US) (0.101 kg)
Standards CSA C22.2 No 14 EN/IEC 60947-5-1 EN/ISO 12100 EN/IEC 60204-1 UL 508 ISO 14119
Product Certifications BG UL CSA
Protective Treatment TH
Ambient Air Temp For Op -13…185 °F (-25…85 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
Vibration Resistance 10 gn 10…150 Hz)IEC 60068-2-6
Shock Resistance 30 gn 11 ms IEC 60068-2-27
Sensitivity To Magnetic Fields 0.3 mT
Electrical Shock Protect Class Class II EN/IEC 61140
IP Degree Of Protection IP66 IEC 60529 IP67 IEC 60529
Category 22411 - LIMIT SWITCHES,IEC,XCKJ
Discount Schedule T
GTIN 03389110971736
Nbr. Of Units In Pkg. 1
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews