Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Circuit breaker Masterpact MTZ3 63H1, 6300 A, 3P drawout, without Micrologic
LV848348
Circuit breaker Masterpact MTZ3 63H1, 6300 A, 3P drawout, without Micrologic
Specifications
Part Number LV848348
UPC 606480824234
UPC11 60648082423
EAN 3606480824234
UNSPSC 39121601
Prop 65 This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
RoHS Compliant Yes
Depth 11.81 inch
Height 11.81 inch
Width 26.30 inch
Characteristics
Range Masterpact
Product Name Masterpact MTZ3
Device Short Name MTZ3 63 H1
Product Or Component Type Circuit breaker
Device Application Protection
Poles Description 3P
Network Type AC
Network Frequency 50/60 Hz
Rating Code H1
Suitability For ISOlation Yes IEC 60947-2
Selectivity Category Category B
Control Type Push-button
Mounting Mode Drawout
Mounting Support Rails Base plate
In Rated Current 6300 A 104 °F (40 °C)
Ui Rated Insulation Voltage 1000 V AC 50/60 Hz IEC 60947-2
Uimp Rated Imp Wstd Voltage 12 kVIEC 60947-2
Icm Rated Sc Making Cap 220 kA 220/415 V AC 50/60 Hz 220 kA 440 V AC 50/60 Hz 220 kA 500/525 V AC 50/60 Hz 220 kA 660/690 V AC 50/60 Hz
Ue Rated Operational Voltage 690 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Ct Rating 6300 A
Performance Level 100 kA Icu 220/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500/525 V AC 50/60 Hz IEC 60947-2 100 kA Icu 660/690 V AC 50/60 Hz IEC 60947-2
Ics Rated Service Breaking Cap 100 kA 220/415 V AC 50/60 Hz IEC 60947-2 100 kA 440 V AC 50/60 Hz IEC 60947-2 100 kA 500/525 V AC 50/60 Hz IEC 60947-2 100 kA 660/690 V AC 50/60 Hz IEC 60947-2
Mechanical Durability 10000 cycles with periodic preventive maintenance IEC 60947-2
Electrical Durability AC-3 6000 cycles 440/690 V AC 50/60 Hz IEC 60947-3 1500 cycles 440 V AC 50/60 Hz IEC 60947-2 1500 cycles 690 V AC 50/60 Hz IEC 60947-2 AC-23A 1500 cycles 440 V AC 50/60 Hz IEC 60947-3 AC-23A 1500 cycles 690 V AC 50/60 Hz IEC 60947-3
Connection Pitch 9.06 in (230 mm)
Icw Rated Short-Time Wstd Crrt 100 kA 0.5 s IEC 60947-2 100 kA 1 s IEC 60947-2 100 kA 3 s IEC 60947-2
Maximum Breaking Time 25 ms
Closing Response Time 80 ms
Height Drawout circuit breaker without chassis 11.81 in (300 mm) Drawout circuit breaker with chassis 18.86 in (479 mm)
Width Drawout circuit breaker without chassis 26.30 in (668 mm) Drawout circuit breaker with chassis 30.94 in (786 mm)
Depth Drawout circuit breaker without chassis 11.81 in (300 mm) Drawout circuit breaker with chassis 15.87 in (403 mm)
Standards IEC 60947-2 IEC 60364-8-1
Product Certifications ASTA
Pollution Degree 3 IEC 60947-1
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
GTIN 03606480824234
Green Premium Status Green Premium product
EU RoHs Directive Compliant
Mercury Free Yes
Pvc Free Yes
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews