| Part Number | LV846454 |
|---|---|
| UPC | 606481155436 |
| UPC11 | 60648115543 |
| EAN | 3606481155436 |
| UNSPSC | 39121601 |
| Prop 65 | This product can expose you to chemicals including: DINP and DIDP which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Depth | 8.17 inch |
| Height | 10.22 inch |
| Width | 9.31 inch |
| Range | Masterpact |
|---|---|
| Product Name | Masterpact MTZ1 |
| Device Short Name | MTZ1 16 H3 |
| Product Or Component Type | Circuit breaker |
| Device Application | Protection |
| Poles Description | 3P |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Rating Code | H3 |
| Suitability For ISOlation | Yes IEC 60947-2 |
| Selectivity Category | Category B |
| Control Type | Push-button |
| Mounting Mode | Drawout |
| Mounting Support | Rails Base plate |
| In Rated Current | 1600 A 104 °F (40 °C) |
| Ui Rated Insulation Voltage | 1000 V AC 50/60 Hz IEC 60947-2 |
| Uimp Rated Imp Wstd Voltage | 12 kVIEC 60947-2 |
| Icm Rated Sc Making Cap | 145 kA 220/415 V AC 50/60 Hz 145 kA 440 V AC 50/60 Hz |
| Ue Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Circuit Breaker Ct Rating | 630 A 1250 A 1600 A 400 A 800 A 1000 A |
| Performance Level | 66 kA Icu 220...415 V AC 50/60 Hz IEC 60947-2 66 kA Icu 440 V AC 50/60 Hz IEC 60947-2 |
| Ics Rated Service Breaking Cap | 50 kA 440 V AC 50/60 Hz IEC 60947-2 50 kA 220...415 V AC 50/60 Hz IEC 60947-2 |
| Mechanical Durability | 10000 cycles with periodic preventive maintenance IEC 60947-2 |
| Icw Rated Short-Time Wstd Crrt | 30 kA 3 s IEC 60947-2 50 kA 1 s IEC 60947-2 50 kA 0.5 s IEC 60947-2 |
| Maximum Breaking Time | 25 ms |
| Closing Response Time | 50 ms |
| Height | Drawout circuit breaker without chassis 10.22 in (259.5 mm) Drawout circuit breaker with chassis 12.68 in (322 mm) |
| Width | Drawout circuit breaker without chassis 9.31 in (236.5 mm) Drawout circuit breaker with chassis 11.34 in (288 mm) |
| Depth | Drawout circuit breaker without chassis 8.17 in (207.5 mm) Drawout circuit breaker with chassis 10.47 in (266 mm) |
| Pollution Degree | 3 IEC 60947-1 |
| Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
| GTIN | 03606481155436 |
| Nbr. Of Units In Pkg. | 1 |
| Green Premium Status | Green Premium product |
| EU RoHs Directive | Compliant |
| Mercury Free | Yes |