| Part Number | TM7NCOM16B |
|---|---|
| Country of Origin | AT |
| UPC | 785901988687 |
| UPC11 | 78590198868 |
| EAN | 3595864092799 |
| Availability | N |
| Lead Time | 61 |
| UNSPSC | 32151703 |
| ECCN | EAR99 |
| HTs Code | 8536904000 |
| Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | PC12 |
| Return Indicator | No |
| Weight | 0.71 pound |
| Range Of Product | Modicon TM7 |
|---|---|
| Product Or Component Type | CANopen interface I/O block |
| Range Compatibility | Modicon LMC058 Modicon M258 |
| Enclosure Material | Plastic |
| Bus Type | CANopen |
| Ue Rated Operational Voltage | 24 V DC |
| Input/Output Number | 16 |
| Input/Output Number Of Block | 16 I/O |
| Discrete Input Number | 0…16 configurable by software |
| Discrete Input Voltage | 24 V |
| Discrete Input Voltage Type | DC |
| Discrete Input Current | 4.4 mA |
| Discrete Input Logic | Positive |
| Discrete Output Number | 0…16 configurable by software |
| Discrete Output Voltage | 24 V |
| Discrete Output Voltage Type | DC |
| Discrete Output Current | <= 0.5 A |
| Discrete Output Type | Transistor |
| Sensor Power Supply | 24 V, 500 mA for all channels overload, short-circuit and reverse polarity protection |
| Electrical Connection | 1 male connector M12 - A coding - 5 ways CANopen bus IN 1 female connector M12 - B coding - 4 ways TM7 bus OUT 1 male connector M8 - 4 ways power IN 1 female connector M8 - 4 ways power OUT 1 female connector M12 - A coding - 5 ways CANopen bus OUT 16 female connectors M8 - 3 ways sensor or actuator |
| Local Signalling | Bus diagnostic 2 LEDs Actuator power supply diagnostics 1 LED Sensor power supply diagnostics 1 LED |
| Operating Position | Any position |
| Fixing Mode | By 2 screws |
| Product Weight | 0.71 lb(US) (0.32 kg) |
| Standards | IEC 61131-2 |
| Product Certifications | GOST-R C-tick ATEX II 3g EEx nA II T5 CURus |
| Marking | CE |
| Ambient Air Temp For Op | 14…140 °F (-10…60 °C) |
| Ambient Air Temp For Storage | -13…185 °F (-25…85 °C) |
| Relative Humidity | 5…95 % without condensation or dripping water |
| Pollution Degree | 2 IEC 60664 |
| IP Degree Of Protection | IP67 IEC 61131-2 |
| Operating Altitude | 0...6561.68 ft (0...2000 m) |
| Storage Altitude | 0.00…9842.52 ft (0…3000 m) |
| Vibration Resistance | 7.5 mm constant amplitude 2…8 Hz)IEC 60721-3-5 Class 5M3 2 gn constant acceleration 8…200 Hz)IEC 60721-3-5 Class 5M3 4 gn constant acceleration 200…500 Hz)IEC 60721-3-5 Class 5M3 |
| Shock Resistance | 30 gn 11 ms IEC 60721-3-5 Class 5M3 |
| Resist Electrostatic Dischrg | 6 kV in contact EN/IEC 61000-4-2 8 kV in air EN/IEC 61000-4-2 |
| Resist To Electromagn Fields | 9.14 V/m (10 V/m) 0.08…2 Hz EN/IEC 61000-4-3 0.91 V/m (1 V/m) 2…2.7 Hz EN/IEC 61000-4-3 |
| Resistance To Fast Transients | 2 kV EN/IEC 61000-4-4 power supply) 1 kV EN/IEC 61000-4-4 input/output) 1 kV EN/IEC 61000-4-4 shielded cable) |
| Surge Withstand For Dc 24 V Circuit | 1 kV power supply (common mode) EN/IEC 61000-4-5 0.5 kV power supply (differential mode) EN/IEC 61000-4-5 1 kV unshielded links (common mode) EN/IEC 61000-4-5 0.5 kV unshielded links (differential mode) EN/IEC 61000-4-5 1 kV shielded links (common mode) EN/IEC 61000-4-5 0.5 kV shielded links (differential mode) EN/IEC 61000-4-5 |
| Electromagnetic Compatibility | EN/IEC 61000-4-6 |
| Disturbance Radiated/Conducted | CISPR 11 |
| Category | 22532 - M258 PLC |
| Discount Schedule | PC12 |
| GTIN | 00785901988687 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | AT |
| Green Premium Status | Green Premium product |
| REACh Free Of SVHC | Yes |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |