| Part Number | K115C503HP |
|---|---|
| Country of Origin | AT |
| UPC | 389110080315 |
| UPC11 | 38911008031 |
| EAN | 3389110080315 |
| Availability | N |
| Lead Time | 33 |
| UNSPSC | 39122214 |
| ECCN | EAR99 |
| HTs Code | 8536509025 |
| Prop 65 | This product can expose you to chemicals including: Nickel compounds and Di-isodecyl phthalate (DIDP) which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov |
| RoHS Compliant | Yes |
| Discount Schedule | CS1 |
| Return Indicator | No |
| Weight | 1.59 pound |
| Range Of Product | Harmony K |
|---|---|
| Product Or Component Type | Complete cam switch |
| Component Name | K115 |
| Ith Cnvtl Free Air Therm Crrt | 115 A |
| Product Mounting | Rear mounting |
| Fixing Mode | 4 holes |
| Cam Switch Head Type | With front plate 88 x 88 mm |
| Type Of Operator | Black handle |
| Rotary Handle Padlocking | Without |
| Presentation Of Legend | With metallic, OFF-ON black |
| Cam Switch Function | Switch |
| Return | Without |
| Off Position | With Off position |
| Poles Description | 3P |
| Switching Positions | Right: 0° - 90° |
| IP Degree Of Protection | IP40 IEC 529 IP40 NF C 20-010 |
| Switching Angle | 90 ° |
| Ui Rated Insulation Voltage | 690 V 3)EN 60947-1 690 V 3)IEC 60947-1 |
| Rated Opr Power In W | 13000 W AC-3, 380/440 V 1 phase EN/IEC 60947-3 15000 W AC-23A, 220/240 V 1 phase EN/IEC 60947-3 15000 W AC-3, 220/240 V 3 phase EN/IEC 60947-3 22000 W AC-23A, 380/440 V 1 phase EN/IEC 60947-3 30000 W AC-23A, 220/240 V 3 phase EN/IEC 60947-3 30000 W AC-3, 380/440 V 3 phase EN/IEC 60947-3 30000 W AC-3, 660/690 V 3 phase EN/IEC 60947-3 3700 W AC-3, 110 V 1 phase EN/IEC 60947-3 45000 W AC-23A, 380/440 V 3 phase EN/IEC 60947-3 5500 W AC-23A, 110 V 1 phase EN/IEC 60947-3 65000 W AC-23A, 660/690 V 3 phase EN/IEC 60947-3 7500 W AC-3, 220/240 V 1 phase EN/IEC 60947-3 |
| Ie Rated Operational Crrt Ac | 100 A AC-21A EN/IEC 60947-3 |
| Short-Circuit Current | 15000 A |
| Short-Circuit Protection | 125 A cartridge fuse gG |
| Uimp Rated Imp Wstd Voltage | 6 kV EN 947-1 6 kV IEC 947-1 |
| Contact Operation | Slow-break |
| Positive Opening | With |
| Electrical Connection | Captive screw clamp terminals flexible 1 x 25 mm² Captive screw clamp terminals solid 1 x 35 mm² |
| Tightening Torque | 22.13 lbf.in (2.5 N.m) |
| Switching Capacity In Ma | 100000 mA DC 140 V 3 resistive 1 ms) 100000 mA DC 24 V 1 inductive 50 ms) 100000 mA DC 48 V 1 resistive 1 ms) 100000 mA DC 48 V 2 inductive 50 ms) 100000 mA DC 70 V 3 inductive 50 ms) 100000 mA DC 95 V 2 resistive 1 ms) 115000 mA DC 24 V 1 resistive 1 ms) 115000 mA DC 48 V 2 resistive 1 ms) 115000 mA DC 70 V 3 resistive 1 ms) 33000 mA DC 30 V 1 inductive 50 ms) 33000 mA DC 60 V 2 inductive 50 ms) 33000 mA DC 90 V 3 inductive 50 ms) |
| Mechanical Durability | 300000 cycles |
| Cad Overall Width | 3.46 in (88 mm) |
| Cad Overall Height | 3.46 in (88 mm) |
| Cad Overall Depth | 11.06 in (281 mm) |
| Product Weight | 1.59 lb(US) (0.72 kg) |
| Standards | EN/IEC 60947-3 |
| Product Certifications | CULus 120 V 5 hp 1 phase CULus 240 V 10 hp 1 phase CULus 240 V 20 hp 3 phase CULus 480 V 30 hp 3 phase |
| Protective Treatment | TC |
| Ambient Air Temp For Op | -13…131 °F (-25…55 °C) |
| Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
| Electrical Shock Protect Class | Class II IEC 60536 Class II NF C 20-030 |
| Category | 21446 - 9003 K CAM SWITCHES |
| Discount Schedule | CS1 |
| GTIN | 03389110080315 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | AT |
| REACh Free Of SVHC | Yes |
| EU RoHs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Warranty | 18 months |