Part Number | ZB4BW0G654 |
---|---|
UPC | 389110894387 |
UPC11 | 38911089438 |
EAN | 3389110894387 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Range Of Product | Harmony XB4 |
---|---|
Product Or Component Type | Complete body/contact assembly and light block |
Device Short Name | ZB4 |
Fixing Collar Material | Zamak |
Sale Per Indivisible Qty | 1 |
Head Type | Standard |
Contacts Type And Composition | 1 NO + 1 NC |
Contact Operation | Slow-break |
Connections - Terminals | Plug-in connector |
Light Source | Protected LED |
Bulb Base | Integral LED |
Light Block Supply | Direct |
Light Source Colour | Blue |
Us Rated Supply Voltage | 110...120 V AC 50/60 Hz |
Cad Overall Width | 1.18 in (30 mm) |
Cad Overall Height | 1.85 in (47 mm) |
Terminals Description ISO n°1 | (11-12)NC |
Contacts Usage | Standard |
Positive Opening | With EN/IEC 60947-5-1 appendix K |
Operating Travel | 0.06 in (1.5 mm) NC changing electrical state) 0.10 in (2.6 mm) NO changing electrical state) 0.17 in (4.3 mm) total travel) |
Operating Force | 2 N NC changing electrical state 2.3 N NO changing electrical state |
Operating Torque | 0.44 lbf.in (0.05 N.m) NO changing electrical state |
Mechanical Durability | 5000000 cycles |
Contacts Material | Silver alloy (Ag/Ni) |
Short-Circuit Protection | 4 A cartridge fuse gG EN/IEC 60947-5-1 |
Ith Cnvtl Free Air Therm Crrt | 10 A EN/IEC 60947-5-1 |
Ui Rated Insulation Voltage | 250 V 3)EN/IEC 60947-1 |
Uimp Rated Imp Wstd Voltage | 4 kV EN 60947-1 |
Ie Rated Operational Current | 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 0.22 A 125 V, DC-13, R300 EN/IEC 60947-5-1 |
Electrical Durability | 1000000 cycles, AC-15, 1 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 1.5 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.15 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C |
Electrical Reliability | Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4 Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4 |
Signalling Type | Steady |
Current Consumption | 14 mA |
Service Life | 100000 h at rated voltage and 25 °C |
Surge Withstand | 1 kV IEC 61000-4-5 |
Protective Treatment | TH |
Ambient Air Temp For Storage | -40…158 °F (-40…70 °C) |
Ambient Air Temp For Op | -40…158 °F (-40…70 °C) |
Electrical Shock Protect Class | Class I IEC 60536 |
Standards | UL 508 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60947-5-5 EN/IEC 60947-1 EN/IEC 60947-5-4 JIS C8201-5-1 JIS C8201-1 |
Product Certifications | CSA BV GL DNV UL Listed RINA LROS (Lloyds register of shipping) |
Vibration Resistance | 5 gn 2…500 Hz)IEC 60068-2-6 |
Shock Resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Resistance To Fast Transients | 2 kV IEC 61000-4-4 |
Resist To Electromagn Fields | 9.14 V/m (10 V/m) IEC 61000-4-3 |
Resist Electrostatic Dischrg | 6 kV on contact (on metal parts) IEC 61000-2-6 8 kV in free air (in insulating parts) IEC 61000-2-6 |
Electromagnetic Emission | Class B IEC 55011 |
GTIN | 03389110894387 |
Nbr. Of Units In Pkg. | 1 |
Green Premium Status | Green Premium product |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366