TeSys island analog IO module, 2 analog inputs, 1 analog output. Connected to a TPRBC bus coupler it is used for advanced control functions (TeSys avatars). Two analog inputs can be configured for measurement of voltage (-10/+10V, 0/+10V), current (0-20mA, 4-20mA) or temperature probes (Ni, Pt, thermocouples). One analog output can be configured for driving voltage source (-10/+10V, 0/+10V) or current source (0-20mA, 4-20mA). Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Add to Quote Catalogue| Part Number | TPRAN2X1 |
|---|---|
| Country of Origin | ID |
| UPC | 606489832704 |
| UPC11 | 60648983270 |
| EAN | 3606489832902 |
| Availability | N |
| Lead Time | 16 |
| ECCN | EAR99 |
| HTs Code | 8517620090 |
| RoHS Compliant | Yes |
| Discount Schedule | I12 |
| Return Indicator | Yes |
| Depth | 4.49 inch |
| Height | 4.65 inch |
| Width | 0.98 inch |
| Weight | 0.38 pound |
| Range | TeSys |
|---|---|
| Product Name | TeSys island |
| Device Short Name | TPRAN |
| Product Or Component Type | Analog IO module |
| Device Presentation | IO module providing 2 analog inputs and 1 analog output Enabling advanced control functions in a TeSys island system Operational only when connected to a bus coupler TPRBC |
| Function Of Module | Measurement of voltage, current or temperature on 2 configurable analog inputs Driving voltage or current source on 1 configurable analog output |
| Product Compatibility | TPRBC bus coupler |
| Analogue Input Number | 2 |
| Analogue Input Type | Current 4...20 mA Current 0...20 mA Voltage 0...10 V Voltage - 10...10 V Temperature probe - 60...180 °C Ni 100 Temperature probe - 60...180 °C Ni 1000 Temperature probe -200...+850 °C Pt 100 Temperature probe - 200...600 °C Pt 1000 Thermocouple - 200...1000 °C thermocouple J Thermocouple - 200...1300 °C thermocouple K Thermocouple 0...1760 °C thermocouple R Thermocouple 0...1760 °C thermocouple S Thermocouple 0...1820 °C thermocouple B Thermocouple - 200...400 °C thermocouple T Thermocouple - 200...1300 °C thermocouple N Thermocouple - 200...800 °C thermocouple E Thermocouple 0...2315 °C thermocouple C |
| Measurement Accuracy | +/- 0.1 % of full scale +/- 0.1 % of full scale +/- 0.1 % of full scale +/- 0.1 % of full scale in positive temperature range +/- 0.4 % of full scale in negative temperature range |
| Analogue Input Resolution | 15 bits + sign |
| Input Impedance | <= 50 Ohm current >= 1 MOhm voltage >= 1 MOhm thermocouple >= 1 MOhm temperature probe |
| Analogue Output Number | 1 isolated |
| Analogue Output Type | Current 4...20 mA Current 0...20 mA Voltage 0...10 V Voltage - 10...10 V |
| Analogue Output Resolution | 4...20 mA, full scale 0...20 mA, full scale 0...10 V, full scale - 10...10 V, full scale |
| Type Of Cable | Twisted shielded pairs cable <98.43 ft (30 m) input/output |
| Local Signalling | DS (device status) 1 LED green/red) |
| Us Rated Supply Voltage | 24 V DC supplied by the bus coupler |
| Current Consumption | 160 mA |
| Power Dissipation In W | 0.5 W maximum |
| Uimp Rated Imp Wstd Voltage | 0.5 kV IEC 61010-1 |
| Standards | IEC 61010-2-201 UL 61010-2-201 CSA C22.2 No 61010-2-201 |
| Product Certifications | CSA UL EAC (pending) |
| Mounting Mode | Horizontal and vertical 35 mm symmetrical rail) |
| Connections - Terminals | Input/output circuit removable spring terminal block 8 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)rigid Input/output circuit removable spring terminal block 8 0.00…0.00 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Input/output circuit removable spring terminal block 8 0.00…0.00 in² (0.25…2.5 mm²) AWG 22...AWG 14)flexible with cable end |
| Width | 0.98 in (25 mm) |
| Height | 4.65 in (118 mm) |
| Depth | 4.49 in (114 mm) |
| Product Weight | 0.38 lb(US) (0.172 kg) |
| Ambient Air Temp For Storage | -13…158 °F (-25…70 °C) |
| Ambient Air Temp For Op | 14…140 °F (-10…60 °C) |
| Relative Humidity | 5…95 % |
| Operating Altitude | 0...6561.68 ft (0...2000 m) without derating |
| IP Degree Of Protection | IP20 |
| Pollution Degree | 2 |
| Protective Treatment | TC |
| Fire Resistance | 1760 °F (960 °C) UL 94 |
| Shock Resistance | 15 gn 11 ms) IEC 60068-2-27 |
| Vibration Resistance | 1.5 mm peak to peak 3…13 Hz) IEC 60068-2-6 1 gn 13…200 Hz) IEC 60068-2-6 |
| Electromagnetic Compatibility | Electrostatic discharge immunity test, level 3 8 kV air, 6 kV contact)EN/IEC 61000-4-2) Radiated RF fields, level 3 10 V/m)EN/IEC 61000-4-3) Fast transients immunity test, level 3 2 kV)EN/IEC 61000-4-4) Surge immunity test, level 3 2 kV)EN/IEC 61000-4-5) |
| Category | 22353 - TESYS ISLAND AUXILIARY DEVICES |
| Discount Schedule | I12 |
| GTIN | 03606489832704 |
| Nbr. Of Units In Pkg. | 1 |
| Country Of Origin | ID |
| EU RoHs Directive | Compliant |
| Mercury Free | Yes |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
| Halogen Content Performance | Halogen free plastic parts product |
| Warranty | 18 months |
Powered by ![]()
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366