TeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 4kW@400V. It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Add to Quote CataloguePart Number | LUCC18BL |
---|---|
Country of Origin | FR |
UPC | 785901550716 |
UPC11 | 78590155071 |
EAN | 3389110364507 |
Availability | N |
Lead Time | 21 |
UNSPSC | 39121521 |
ECCN | EAR99 |
HTs Code | 8536304000 |
RoHS Compliant | Yes |
Discount Schedule | I11 |
Return Indicator | No |
Depth | 2.36 inch |
Height | 2.60 inch |
Width | 1.77 inch |
Range Of Product | TeSys U |
---|---|
Range | TeSys |
Product Name | TeSys U |
Device Short Name | LUCC |
Product Or Component Type | Advanced control unit |
Device Application | Motor control Motor protection |
Product Specific Application | Basic protection and advanced functions, communication |
Main Function Available | Manual reset Earth fault protection Protection against phase failure and phase imbalance Protection against overload and short-circuit |
Product Compatibility | Power base LUB32 Power base LUB38 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B32BL Reversing contactor breaker LU2B38BL |
Ue Rated Operational Voltage | 690 V AC |
Network Frequency | 40...60 Hz |
Load Type | Single-phase motor |
Utilisation Category | AC-44 AC-43 AC-41 |
Motor Power kW | 4 kW 400...440 V AC 50/60 Hz 1 phase |
Rated Motor Current Adjustment Range | 4.5…18 A |
Thermal Overload Class | Class 10 40…60 Hz -13…131 °F (-25…55 °C) IEC 60947-6-2 Class 10 40…60 Hz -13…131 °F (-25…55 °C) UL 508 |
Tripping Threshold | 14.2 x Ir +/- 20 % |
[Uc] Control Circuit Voltage | 24 V DC |
Ctrl Circuit Voltage Limits | 20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out |
Typical Current Consumption | 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38 |
Heat Dissipation | 3 W control circuit with LUB32 3 W control circuit with LUB38 |
Operating Time | 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit |
Reset | Manual reset |
Standards | EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier |
Product Certifications | CE UL CSA CCC EAC ASEFA ATEX Marine |
Ui Rated Insulation Voltage | 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 |
Uimp Rated Imp Wstd Voltage | 6 kV IEC 60947-6-2 |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Fixing Mode | Plug-in front face) |
Width | 1.77 in (45 mm) |
Height | 2.60 in (66 mm) |
Depth | 2.36 in (60 mm) |
Compatibility Code | LUCC |
IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1 |
Protective Treatment | TH IEC 60068 |
Ambient Air Temp For Op | -13…158 °F (-25…70 °C) |
Ambient Air Temp For Storage | -40…185 °F (-40…85 °C) |
Operating Altitude | 6561.68 ft (2000 m) |
Fire Resistance | 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12 |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27 |
Vibration Resistance | 2 gn 5…300 Hz power poles open IEC 60068-2-6 4 gn 5…300 Hz power poles closed IEC 60068-2-6 |
Resist Electrostatic Dischrg | 8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2 |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Imm To Radioelectric Fields | 10 V IEC 61000-4-6 |
Immunity To Microbreaks | 3 ms |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
Category | 22397 - TESYS U - CNTRL MOD(LUCA,LUCD) |
Discount Schedule | I11 |
GTIN | 00785901550716 |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366