Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
Advanced control unit, TeSys U, 0.15-0.6A, 1P motors, protection & diagnostic, class 10, coil 24V DC
LUCCX6BL
Advanced control unit, TeSys U, 0.15-0.6A, 1P motors, protection & diagnostic, class 10, coil 24V DC

TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 0.04kW@400V. It provides full protection to motors with a rated current Ir 0.15-0.6A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Add to Quote Catalogue
Specifications
Part Number LUCCX6BL
Country of Origin FR
UPC 785901665977
UPC11 78590166597
EAN 3389110364460
Availability N
Lead Time 21
UNSPSC 39121521
ECCN EAR99
HTs Code 8536304000
RoHS Compliant Yes
Discount Schedule I11
Return Indicator No
Depth 2.36 inch
Height 2.60 inch
Width 1.77 inch
Characteristics
Range Of Product TeSys U
Range TeSys
Product Name TeSys U
Device Short Name LUCC
Product Or Component Type Advanced control unit
Device Application Motor control Motor protection
Product Specific Application Basic protection and advanced functions, communication
Main Function Available Protection against phase failure and phase imbalance Protection against overload and short-circuit Earth fault protection Manual reset
Product Compatibility Power base LUB12 Power base LUB32 Power base LUB38 Power base LUB120 Power base LUB320 Power base LUB380 Reversing contactor breaker LU2B12BL Reversing contactor breaker LU2B32BL Reversing contactor breaker LU2B38BL
Ue Rated Operational Voltage 690 V AC
Network Frequency 40...60 Hz
Load Type Single-phase motor
Utilisation Category AC-43 AC-41 AC-44
Rated Motor Current Adjustment Range 0.15…0.6 A
Thermal Overload Class Class 10 40…60 Hz -13…131 °F (-25…55 °C) IEC 60947-6-2 Class 10 40…60 Hz -13…131 °F (-25…55 °C) UL 508
Tripping Threshold 14.2 x Ir +/- 20 %
[Uc] Control Circuit Voltage 24 V DC
Ctrl Circuit Voltage Limits 20...27 V DC 24 V in operation 14.5 V DC 24 V drop-out
Typical Current Consumption 130 mA 24 V DC I maximum while closing with LUB12 220 mA 24 V DC I maximum while closing with LUB32 220 mA 24 V DC I maximum while closing with LUB38 60 mA 24 V DC I rms sealed with LUB12 80 mA 24 V DC I rms sealed with LUB32 80 mA 24 V DC I rms sealed with LUB38
Heat Dissipation 2 W control circuit with LUB12 3 W control circuit with LUB32 3 W control circuit with LUB38
Operating Time 35 ms opening with LUB12 control circuit 35 ms opening with LUB32 control circuit 35 ms opening with LUB38 control circuit 70 ms closing with LUB12 control circuit 70 ms closing with LUB32 control circuit 70 ms closing with LUB38 control circuit
Reset Manual reset
Standards EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Product Certifications CE UL CSA CCC EAC ASEFA ATEX Marine
Ui Rated Insulation Voltage 690 V IEC 60947-6-2 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
Uimp Rated Imp Wstd Voltage 6 kV IEC 60947-6-2
Safe Separation Of Circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Fixing Mode Plug-in front face)
Width 1.77 in (45 mm)
Height 2.60 in (66 mm)
Depth 2.36 in (60 mm)
Compatibility Code LUCC
IP Degree Of Protection IP20 front panel and wired terminals IEC 60947-1 IP20 other faces IEC 60947-1 IP40 front panel outside connection zone IEC 60947-1
Protective Treatment TH IEC 60068
Ambient Air Temp For Op -13…158 °F (-25…70 °C)
Ambient Air Temp For Storage -40…185 °F (-40…85 °C)
Operating Altitude 6561.68 ft (2000 m)
Fire Resistance 1760 °F (960 °C) parts supporting live components IEC 60695-2-12 1202 °F (650 °C) IEC 60695-2-12
Shock Resistance 10 gn power poles open IEC 60068-2-27 15 gn power poles closed IEC 60068-2-27
Vibration Resistance 2 gn 5…300 Hz power poles open IEC 60068-2-6 4 gn 5…300 Hz power poles closed IEC 60068-2-6
Resist Electrostatic Dischrg 8 kV 3 in open air IEC 61000-4-2 8 kV 4 on contact IEC 61000-4-2
Resistance To Radiated Fields 9.14 V/m (10 V/m) 3 IEC 61000-4-3
Resistance To Fast Transients 2 kV 3 serial link IEC 61000-4-4 4 kV 4 all circuits except for serial link IEC 61000-4-4
Imm To Radioelectric Fields 10 V IEC 61000-4-6
Immunity To Microbreaks 3 ms
Immunity To Voltage Dips 70 % / 500 ms IEC 61000-4-11
Category 22397 - TESYS U - CNTRL MOD(LUCA,LUCD)
Discount Schedule I11
GTIN 00785901665977
Nbr. Of Units In Pkg. 1
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews