Part Number | RE10RMMU |
---|---|
UPC | 606480914577 |
UPC11 | 60648091457 |
EAN | 3606480914577 |
UNSPSC | 39121523 |
Prop 65 | This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov |
RoHS Compliant | Yes |
Weight | 0.13 pound |
Range Of Product | Zelio Time |
---|---|
Product Or Component Type | Modular timing relay |
Discrete Output Type | Relay |
Component Name | RE11R |
Time Delay Type | D H B Ht Ac Bw C Di At A |
Time Delay Range | 10...100 h 0.1...1 s 1...10 h 6...60 s 1...10 s 1...10 min 6...60 min |
[Us] Rated Supply Voltage | 24 V DC 24...240 V AC 50/60 Hz |
Nominal Output Current | 8 A |
Contacts Material | AgNi (cadmium free) |
Width Pitch Dimension | 0.69 in (17.5 mm) |
Control Type | Selector switch front panel |
Voltage Range | 0.85...1.1 Us |
Connections - Terminals | Screw terminals, 2 x 1.5 mm² without cable end Screw terminals, 2 x 2.5 mm² + 1 x 4 mm² with cable end |
Housing Material | Self-extinguishing |
Repeat Accuracy | +/- 0.5 % IEC 61812-1 |
Temperature Drift | +/- 0.05 %/°C |
Voltage Drift | +/- 0.2 %/V |
Setting Accuracy Of Time Delay | +/- 10 % of full scale 25 °C IEC 61812-1 |
Minimum Pulse Duration | 100 ms with load in parallel 30 ms |
Reset Time | 100 ms on de-energisation |
On-Load Factor | 100 % |
Power Consumption In Va | 32 VA 240 V |
Power Consumption In W | 0.6 W 24 V 1.5 W 240 V |
Minimum Switching Current | 10 mA |
Maximum Switching Current | 8 A |
Maximum Switching Voltage | 250 V |
Breaking Capacity | 2000 VA |
Breaking Capacity | 80 W |
Electrical Durability | 100000 cycles 8 A, 250 V resistive |
Mechanical Durability | 5000000 cycles |
Uimp Rated Imp Wstd Voltage | 5 kV 1.2…50 µs IEC 60664-1 5 kV 1.2…50 µs IEC 61812-1 |
Marking | CE |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Mounting Support | 35 mm symmetrical mounting rail EN 50022 |
Local Signalling | LED indicator green, flashing timing in progress LED indicator green, steady relay energised, no timing in progress LED indicator green, blinking relay energised, no timing in progress (except functions Di-D) |
Product Weight | 0.13 lb(US) (0.06 kg) |
Compatibility Code | RE10 |
Immunity To Microbreaks | 10 ms |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
Standards | IEC 60669-2-3 EN 50082-1/2 EN 50081-1/2 IEC 61812-1 |
Directives | 93/68/EEC - low voltage directive 73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility |
Product Certifications | CSA GL CULus |
Ambient Air Temp For Storage | -22…140 °F (-30…60 °C) |
Ambient Air Temp For Op | -4…140 °F (-20…60 °C) |
IP Degree Of Protection | Terminal block IP20 IEC 60529 Housing IP40 IEC 60529 Front panel IP50 IEC 60529 |
Vibration Resistance | 0.35 mm 10…55 Hz)IEC 60068-2-6 |
Relative Humidity | 93 % without condensation IEC 60068-2-3 |
Electromagnetic Compatibility | Electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 Electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV direct)level 3 IEC 61000-4-4 Surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5 Surge immunity test 2 kV common mode)level 3 IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz) IEC 61000-4-6 Immunity to microbreaks and voltage drops 30 % 10 ms) IEC 61000-4-11 Immunity to microbreaks and voltage drops 60 % 100 ms) IEC 61000-4-11 Immunity to microbreaks and voltage drops 95 % 5 s) IEC 61000-4-11 Conducted and radiated emissionsclass B group 1 EN 55022 |
GTIN | 03606480914577 |
Green Premium Status | Green Premium product |
Powered by
Based on 2 User Reviews
1619 Boyd St, Santa Ana, CA 92705
(714) 835-6211
(714) 972-2366