Get a Quote Download Spec Sheet PDFPart No. | Conductors | Color Code | Pull Tension (Max) | Bend Radius (Min) | OD (Nom) | Jacket Thickness | Outer Jacket Thickness | ||||
Lbs | Inch | mm | Inch | mm | Inch | mm | Inch | mm |
Flexible Stranded (16 x 30) TC Conductors • XLPE Insulation • Double LSZH Jackets NOTE: Continuous armor cables are not DNV rated | |||||||||||
W27916Z | 2 | E2 | 44 | 6.98 | 177.4 | 0.58 | 14.8 | 0.05 | 1.1 | 0.06 | 1.4 |
W27325Z | 2 | E2 | 44 | 6.98 | 177.4 | 0.58 | 14.8 | 0.05 | 1.1 | 0.06 | 1.4 |
W28334Z | 3 | E2 | 66 | 7.22 | 183.5 | 0.60 | 15.3 | 0.05 | 1.1 | 0.06 | 1.4 |
W28326Z | 4 | E2 | 88 | 7.58 | 192.6 | 0.63 | 16.1 | 0.05 | 1.1 | 0.06 | 1.4 |
W28335Z | 5 | E2 | 110 | 7.94 | 201.8 | 0.66 | 16.8 | 0.05 | 1.1 | 0.06 | 1.4 |
W28600Z | 6 | E2 | 132 | 8.18 | 207.9 | 0.68 | 17.3 | 0.05 | 1.1 | 0.06 | 1.4 |
W28327Z | 7 | E2 | 154 | 8.30 | 210.9 | 0.69 | 17.6 | 0.05 | 1.1 | 0.06 | 1.4 |
W28601Z | 8 | E2 | 176 | 8.66 | 220.1 | 0.72 | 18.3 | 0.05 | 1.1 | 0.06 | 1.4 |
W28336Z | 9 | E2 | 198 | 9.14 | 232.3 | 0.76 | 19.4 | 0.05 | 1.1 | 0.06 | 1.4 |
W28328Z | 10 | E2 | 220 | 9.98 | 253.6 | 0.83 | 21.1 | 0.06 | 1.5 | 0.06 | 1.4 |
W28602Z | 11 | E2 | 242 | 10.22 | 259.7 | 0.85 | 21.6 | 0.06 | 1.5 | 0.06 | 1.4 |
W28329Z | 12 | E2 | 264 | 10.22 | 259.7 | 0.85 | 21.6 | 0.06 | 1.5 | 0.06 | 1.4 |
W28603Z | 13 | E2 | 286 | 10.58 | 268.8 | 0.88 | 22.4 | 0.06 | 1.5 | 0.06 | 1.4 |
W28604Z | 14 | E2 | 308 | 10.58 | 268.8 | 0.88 | 22.4 | 0.06 | 1.5 | 0.06 | 1.4 |
W28605Z | 15 | E2 | 330 | 10.94 | 278.0 | 0.91 | 23.2 | 0.06 | 1.5 | 0.06 | 1.4 |
W28606Z | 16 | E2 | 352 | 10.94 | 278.0 | 0.91 | 23.2 | 0.06 | 1.5 | 0.06 | 1.4 |
W28607Z | 17 | E2 | 374 | 11.30 | 287.1 | 0.94 | 23.9 | 0.06 | 1.5 | 0.06 | 1.4 |
Flexible Stranded (16 x 30) TC Conductors • XLPE Insulation • Double LSZH Jackets NOTE: Continuous armor cables are not DNV rated | |||||||||||
W28608Z | 18 | E2 | 396 | 11.30 | 287.1 | 0.94 | 23.9 | 0.06 | 1.5 | 0.06 | 1.4 |
W28609Z | 19 | E2 | 418 | 11.30 | 287.1 | 0.94 | 23.9 | 0.06 | 1.5 | 0.06 | 1.4 |
W28610Z | 20 | E2 | 440 | 11.66 | 296.3 | 0.97 | 24.7 | 0.06 | 1.5 | 0.06 | 1.4 |
W28611Z | 25 | E2 | 550 | 12.86 | 326.7 | 1.07 | 27.2 | 0.06 | 1.5 | 0.06 | 1.4 |
W28612Z | 30 | E2 | 660 | 13.10 | 332.8 | 1.09 | 27.7 | 0.06 | 1.5 | 0.06 | 1.4 |
W28613Z | 37 | E2 | 814 | 14.42 | 366.4 | 1.20 | 30.5 | 0.08 | 2.0 | 0.06 | 1.4 |