TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 240 V AC coil

LC2D09U7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 240V 50/60Hz AC coil, 2NO+2NC aux contacts, a mechanical interlock. LC2D09U7 is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 4kW@400V. It includes a 240V 50/60Hz AC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 240V AC coil that can be supplied at 50Hz or 60Hz. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 2 million cycles at 9A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
Product Certifications
  • DNV
  • CSA
  • CCC
  • UL
  • GL
  • LROS (Lloyds register of shipping)
  • BV
  • RINA
  • GOST
  • UKCA
Interlocking Type mechanical
[Uc] Control Circuit Voltage 240 V AC 50/60 Hz
[Ue] Rated Operational Voltage
  • power circuit <= 690 V AC 25...400 Hz
  • power circuit <= 300 V DC
Power Dissipation Per Pole
  • 0.2 W AC-3
  • 1.56 W AC-1
  • 0.2 W AC-3e
Average Impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current
  • 10 A 60 °C signalling circuit
  • 25 A 60 °C power circuit
Mounting Support
  • rail
  • plate
Control Circuit Type AC 50/60 Hz
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 508
  • IEC 60335-1
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application
  • resistive load
  • motor control
Rated Breaking Capacity 250 A 440 V power circuit IEC 60947
Product Or Component Type reversing contactor
Irms Rated Making Capacity
  • 250 A 440 V power circuit IEC 60947
  • 140 A AC signalling circuit IEC 60947-5-1
  • 250 A DC signalling circuit IEC 60947-5-1
Product Name TeSys Deca
Associated Fuse Rating
  • 25 A gG <= 690 V type 1 power circuit
  • 20 A gG <= 690 V type 2 power circuit
  • 10 A gG signalling circuit IEC 60947-5-1
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Connections - Terminals
  • power circuit screw clamp terminals 1 1-4 mm²flexible without cable end
  • power circuit screw clamp terminals 2 1-4 mm²flexible without cable end
  • power circuit screw clamp terminals 1 1-4 mm²flexible with cable end
  • power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end
  • power circuit screw clamp terminals 1 1-4 mm²solid
  • power circuit screw clamp terminals 2 1-4 mm²solid
  • control circuit screw clamp terminals 1 1-4 mm²flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm²flexible without cable end
  • control circuit screw clamp terminals 1 1-4 mm²flexible with cable end
  • control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm²solid
  • control circuit screw clamp terminals 2 1-4 mm²solid
Range
  • TeSys
  • TeSys Deca
Pole Contact Composition 3 NO
Device Presentation preassembled with reversing power busbar
Utilisation Category
  • AC-3
  • AC-1
  • AC-3e
[Ie] Rated Operational Current
  • 9 A 60 °C) <= 440 V AC AC-3 power circuit
  • 25 A 60 °C) <= 440 V AC AC-1 power circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • power circuit 1.7 N.m screw clamp terminals Philips No 2
  • control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.7 N.m screw clamp terminals Philips No 2
  • control circuit 1.7 N.m screw clamp terminals pozidriv No 2
  • power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Electrical Durability
  • 0.6 Mcycles 25 A AC-1 <= 440 V
  • 2 Mcycles 9 A AC-3 <= 440 V
  • 0.6 Mcycles 25 A AC-3e <= 440 V
Mechanical Durability 15 Mcycles
Poles Description 3P
Operating Time
  • 12...22 ms closing
  • 4...19 ms opening
Overvoltage Category III
Motor Power Kw
  • 2.2 kW 220...230 V AC 50-60 Hz
  • 4 kW 380...400 V AC 50-60 Hz
  • 4 kW 415 V AC 50-60 Hz
  • 4 kW 440 V AC 50-60 Hz
  • 5.5 kW 500 V AC 50-60 Hz
  • 5.5 kW 660...690 V AC 50-60 Hz
Maximum Horse Power Rating
  • 0.5 hp 115 V at AC 60 Hz for 1 phase
  • 1 hp 230/240 V at AC 60 Hz for 1 phase
  • 2 hp 200/208 V at AC 60 Hz for 3 phase
  • 2 hp 230/240 V at AC 60 Hz for 3 phase
  • 5 hp 460/480 V at AC 60 Hz for 3 phase
  • 7.5 hp 575/600 V at AC 60 Hz for 3 phase
[Ui] Rated Insulation Voltage
  • power circuit 690 V IEC 60947-4-1
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • signalling circuit 690 V IEC 60947-1
  • signalling circuit 600 V CSA
  • signalling circuit 600 V UL
Device Short Name LC2D
[Icw] Rated Short-Time Withstand Current
  • 30 A 40 °C - 10 min power circuit
  • 61 A 40 °C - 1 min power circuit
  • 105 A 40 °C - 10 s power circuit
  • 210 A 40 °C - 1 s power circuit
  • 100 A - 1 s signalling circuit
  • 120 A - 500 ms signalling circuit
  • 140 A - 100 ms signalling circuit
Protective Cover with
Warranty 18 months
Non-Overlap Time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA signalling circuit
Control Circuit Voltage Limits
  • 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz
  • 0.8...1.1 Uc -40-60 °C operational AC 50 Hz
  • 0.85...1.1 Uc -40-60 °C operational AC 60 Hz
  • 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
Insulation Resistance > 10 MOhm signalling circuit
Inrush Power In Va
  • 70-70 VA 60 Hz 0.75 20 °C)
  • 70-70 VA 50 Hz 0.75 20 °C)
Coil Technology without built-in suppressor module
Minimum Switching Voltage 17 V signalling circuit
Signalling Circuit Frequency 25...400 Hz
Auxiliary Contacts Type
  • mechanically linked 1 NO + 1 NC IEC 60947-5-1
  • mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va
  • 7.5-7.5 VA 60 Hz 0.3 20 °C)
  • 7-7 VA 50 Hz 0.3 20 °C)
Heat Dissipation 2-3 W 50/60 Hz
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP1501004
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile ENVEOLI1501004
Eu Rohs Directive Compliant
Mechanical Robustness
  • vibrations contactor open2 Gn, 5...300 Hz
  • vibrations contactor closed4 Gn, 5...300 Hz
  • shocks contactor open10 Gn for 11 ms
  • shocks contactor closed15 Gn for 11 ms
Ambient Air Temperature For Operation
  • -40-60 °C
  • 60-70 °C with derating
Height 77 mm
Climatic Withstand
  • IACS E10
  • IEC 60947-1 Annex Q category D
Pollution Degree 3
Net Weight 0.687 kg
Flame Retardance V1 conforming to UL 94
Ambient Air Temperature For Storage -60-80 °C
Protective Treatment TH IEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 90 mm