Electrical distributor of high quality products to the LA and Orange County markets

Call Us Today To get a Quote
LC1D80008P7 – IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
LC1D80008P7
IEC contactor, TeSys Deca, nonreversing, 125A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 110A resistive load rating. Contactor is supplied with a 230 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.78 inches wide and 5.51 inches deep. It weighs 4.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Brand: Schneider Electric

Add to Quote Catalogue
Specifications
[Uc] Control Circuit Voltage 230 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz
Range Of Product TeSys Deca
Contactor Application resistive load
Product Or Component Type contactor
Range TeSys
Utilisation Category AC-1
[Ie] Rated Operational Current 125 A 60 °C) <= 440 V AC AC-1 power circuit
Poles Description 4P
Device Short Name LC1D
Warranty 18 months
Power Dissipation Per Pole 12.5 W AC-1
Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
[Ith] Conventional Free Air Thermal Current 125 A 60 °C power circuit
Control Circuit Voltage Limits
  • 0.85...1.1 Uc -40-55 °C operational AC 60 Hz
  • 0.3...0.6 Uc -40-55 °C drop-out AC 50/60 Hz
  • 0.8...1.1 Uc -40-55 °C operational AC 50 Hz
Mounting Support
  • plate
  • rail
Contact Compatibility M1
Control Circuit Type AC 50/60 Hz
Safety Reliability Level
  • B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
  • B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree 3
Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
Irms Rated Making Capacity 1100 A 440 V power circuit IEC 60947
Associated Fuse Rating
  • 200 A gG <= 690 V type 1 power circuit
  • 160 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Inrush Power In Va
  • 245-245 VA 60 Hz 0.75 20 °C)
  • 245-245 VA 50 Hz 0.75 20 °C)
Pole Contact Composition 2 NO + 2 NC
Connections - Terminals
  • control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end
  • control circuit screw clamp terminals 1 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 2 1-4 mm² flexible without cable end
  • control circuit screw clamp terminals 1 1-4 mm² solid without cable end
  • control circuit screw clamp terminals 2 1-4 mm² solid without cable end
  • power circuit connector 1 4-50 mm² flexible without cable end
  • power circuit connector 2 4-25 mm² flexible without cable end
  • power circuit connector 1 4-50 mm² flexible with cable end
  • power circuit connector 2 4-16 mm² flexible with cable end
  • power circuit connector 1 4-50 mm² solid without cable end
  • power circuit connector 2 4-25 mm² solid without cable end
Coil Technology without built-in suppressor module
Operating Time
  • 20...35 ms closing
  • 6...20 ms opening
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque
  • control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm
  • control circuit 1.2 N.m screw clamp terminals Philips No 2
  • power circuit 12 N.m connector flat Ø 6 to Ø 8 mm
  • power circuit 12 N.m connector hexagonal 4 mm
  • control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Electrical Durability 0.8 Mcycles 125 A AC-1 <= 440 V
Mechanical Durability 4 Mcycles
Compatibility Code LC1D
Hold-In Power Consumption In Va
  • 26-26 VA 60 Hz 0.3 20 °C)
  • 26-26 VA 50 Hz 0.3 20 °C)
Overvoltage Category III
[Ui] Rated Insulation Voltage
  • power circuit 600 V CSA
  • power circuit 600 V UL
  • power circuit 1000 V IEC 60947-4-1
[Icw] Rated Short-Time Withstand Current
  • 640 A 40 °C - 10 s power circuit
  • 990 A 40 °C - 1 s power circuit
  • 135 A 40 °C - 10 min power circuit
  • 320 A 40 °C - 1 min power circuit
Heat Dissipation 6-10 W 50/60 Hz
Protective Cover without
Rohs Exemption Information Yes
Mercury Free Yes
Environmental Disclosure ENVPEP110205EN
Sustainable Offer Status Green Premium product
Pvc Free Yes
Toxic Heavy Metal Free Yes
Reach Regulation Free of Substances of Very High Concern above the threshold
California Proposition 65 WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of Svhc Yes
Weee The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation Pro-active China RoHS declaration (out of China RoHS legal scope)
Eu Rohs Directive Compliant
Product Certifications
  • UL
  • CSA
  • CCC
  • EAC
  • UKCA
  • CB
  • EU-RO-MR by DNV-GL
Height 127 mm
Standards
  • EN 60947-4-1
  • EN 60947-5-1
  • IEC 60947-4-1
  • IEC 60947-5-1
  • UL 60947-4-1
  • UL 60947-5-1
  • CSA C22.2 No 60947-4-1
  • CSA C22.2 No 60947-5-1
  • GB/T 14048.4
Climatic Withstand IACS E10 exposure to damp heat
Net Weight 1.84 kg
Flame Retardance V1 conforming to UL 94
Protective Treatment THIEC 60068-2-30
Ip Degree Of Protection IP20 front face IEC 60529
Mechanical Robustness
  • vibrations contactor open 2 Gn, 5...300 Hz)
  • shocks contactor open 8 Gn for 11 ms)
  • vibrations contactor closed 3 Gn, 5...300 Hz)
  • shocks contactor closed 10 Gn for 11 ms)
Operating Altitude 0...9842.52 ft (0...3000 m)
Fire Resistance 850 °C IEC 60695-2-1
Width 96 mm
Depth 140 mm
Permissible Ambient Air Temperature Around The Device
  • -40-60 °C
  • 60-70 °C with derating
Documents
Royal Wholesale Electric

5.0

Powered by

Based on 2 User Reviews